Nr Order No. Specifications
45 71228789 Terminal
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C.
Consists:
Connection terminal 3-Pol stamp 1,2
Connection terminal 2-Pol stamp A, B
Connection terminal 4-Pol stamp 20-23
Connection terminal 4-Pol stamp 24-26.
40 71228790 Split connection plate assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
30 XPD0014- **Electronic Plug-in Promag 400 Index C
Complete main electronic module or
power supply, I /O-board and amplifier
as individual boards.
Complete main electronic module
contains:
Power supply, I /O-board, amplifier
board carrier, terminal connection
ribbon cable, installation marterial.
Individual boards contains:
Installation marterial
Power supply incl. terminal connection/
I /O-board incl. terminal connection/
Amplifier incl. ribbon cable.
L
AA
C6
GR
A
L
A
N
1
2
74
77
44 71615503 wiring board
Usage:
Promag 400(C) sensor L/W non-haz
Promag 800(C) sensor W non-haz.
(C) = generation index C
Sensor connection housing.
Consists of: connection board.
30 XPD0040- Electromagnetic 400 Index C Upgrade
Complete main electronic module or
power supply, I /O module with amplifier
as individual boards.
Complete main electronic module
contains:
Power supply, I /O module, amplifier
board carrier, terminals
ribbon cable, installation marterial.
Individual boards contains:
Installation marterial
Power supply incl. terminals/
I /O module incl. terminal connection and
amplifier incl. ribbon cable.
L
AA
C6
GR
A
L
A
H
I
L
M
N
1
2
66
67
68
70
71
39 71185788 T-DAT module
50 XPD0017- Display Module 4-wire,400 Index C
Usage:
Promag 400 Index C
Prosonic Flow 400 Index B.
1
2
20 71443262 cover
Usage:
Promag 400 (C)
(C) = generation index C.
Consists:
Version 1:
cover polycarbonate complete
2x hinge pin L= 58mm plastic.
Version 2:
cover polycarbonate complete
O-Ring 196,44x3,53 VMQ
wire with screw lock 1,5x150.
20 71384170 Promag400/500 cover
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
transmitter housing Alu.
Consists:
cover Alu complete included
O-Ring 196,40x3,53 HNBR
default and -50oC/-58oF
wire with screw lock 1,5x150.
24 71228796 Gap Assembly
Usage:
Promag 10/500
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
cover Alu
O-Ring 113,90x3,53 HNBR.
24 71228796 Gap Assembly
Usage:
Promag 10/500
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
cover Alu
O-Ring 113,90x3,53 HNBR.
24 71188176 Gap Assembly
Usage:
Promag 10/400/500/800
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
cover plastic coated
O-Ring 91,67 x 3,53 FKM.
25 71278077 cover polycarbonate gasket
Usage:
Prosonic Flow 400
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
Promag 400/800(C)
(C) = generation index C
transmitter housing polycarbonate.
Consists:
10x O-Ring 196,44x3,53 VMQ.
25 71278078 cover sealing ring
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
transmitter housing Alu.
Consists:
10x O-Ring 196,40x3,53 HNBR
default and -50oC/-58oF.
72 71188179 cover sealing ring
Usage:
Promag 10/400/500/800
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
10x O-Ring 91,67 x 3,53 FKM.
71 71228793 Housing Sealing Ring Assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
Consists:
Gasket EPDM for housing/sensor D/L/W.
O-Ring 29,87x1,78 HNBR for sensor-
plug L/W.
73 71228798 Housing Sealing Ring Assembly
Usage:
Promag 10/500
Promag 500 digital
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
O-Ring 113,90x3,53 HNBR for cover
gasket EPDM
housing/sensor L/P/W
O-Ring 29,87x1,78 HNBR for sensor plug.
73 71228798 Housing Sealing Ring Assembly
Usage:
Promag 10/500
Promag 500 digital
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
O-Ring 113,90x3,53 HNBR for cover
gasket EPDM
housing/sensor L/P/W
O-Ring 29,87x1,78 HNBR for sensor plug.
12 71228794 Housing Sealing Ring Assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
Consists:
4x screw M5x18 hex cap DIN912 pla
4x spring washer M5 DIN7980 st.pla
for housing/sensor.
15 71236702 cable plug
15 71236702 cable plug
17 50096840 cable plug
Kit 10 cable glands M20x1,5
15 71236703 Adapter
15 71236703 Adapter
17 50098041 Adapter
Kit 10 extension M20x1.5/G 1/2"
15 71236704 Adapter
15 71236704 Adapter
17 50098042 Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15 71236702 cable plug
15 71236705 cable plug
17 71029350 Sensor Plug
15 71236702 cable plug
15 71236702 cable plug
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236705 cable plug
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236703 Adapter
15 71236703 Adapter
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236704 Adapter
15 71236704 Adapter
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236704 Adapter
15 71236704 Adapter
13 71276494 clamp fastening, screw
Usage: Promass 100, Promag 100
Prosonic Flow E 100/E Heat
CNGmass, LPGmass, LNGmass
Promag/Promass 500, Promag 10
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
Promag 400/800(C)
(C) = generation index C
sensor connection housing.
Consists:
cover clamp, screw M4x16.
82 71228792 Display Protective Cover
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass/
Teqwave MW 500 digital
transmitter housing Alu.
Consists:
display protection 1.4301
installation material.
5X4CXX- Transmitter Conversion Assembly Promag 400
Same housing for compact/remote version.
Corrosion-resistant transmitter version.
With an integrated web server.
Important:
Transmitter only for remote design
(feature 015/A; feature 020/P/N).
Connection board incl. S-DAT of original
transmitter has to be reused in the new
transmitter only.
Conversion kit
(feature 015/ B /C/D/E/F/G/H/ I):
For conversion of an already existing
Promag to the new device generation or
to another device version.
Consists of all required
conversion parts.
AA
C6
GR
A
9
A
M
N
P
9
L
9
H
I
L
M
N
0
1
2
4
5
6
7
9
9
A
B
C
D
L
N
P
U
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AQ
AR
BA
C9
E9
EA
EB
EC
I7
P9
PA
PC
66
67
68
70
71
Z1
Z2
DK5005- Transmitter Mounting Assembly 400
Usage:
Promag 400/800
transmitter advanced.
B
DK5CA- Promag 10/50/51/53/55 Split Cable DK5CA
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
1
2
4
5
6
7
A
DK5GD- Grounding Ring DK5GD
Includes 1 grounding disc/protection
disc
1FA
1FB
1HA
1HB
1ZA
1ZB
25A
25B
2FA
2FB
2HA
2HB
32A
32B
3FA
3FB
3HA
3HB
3SA
3SB
40A
40B
4FA
4FB
4HA
4HB
50A
50B
5HA
5HB
65A
65B
6HA
6HB
7FA
7HA
80A
80B
8HA
RHA
T0A
T2A
V0A
E
H
U
5
7
9
C
D
E
L
P
DK5GC- Ground wire DK5GC
A kit includes 2 cables
1F
1H
1Z
25
2F
2H
32
3F
3H
40
50
65
80
0
5
7
C
D
L
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
CA
1