Nr Order Number Specifications
71310423 display case fixing assembly (3)
Packing unit: 3 pieces
B 71502617 O-ring 88x 3 HNBR 70 ° Shore PTFE_5pcs
Packing unit: 5 pieces
B 71600564 Set O-ring 74x3 75° VMQ Silicon
Packing unit: 5 pieces
TMT142X-DA Spare parts TMT142X
Spare parts TMT142X
TMT142X-DB Spare parts TMT142X
Spare parts TMT142X
TMT142X-DC Spare parts TMT142X
Spare parts TMT142X
B TMT142X-HA Spare parts TMT142X
Spare parts TMT142X
B TMT142X-HC Spare parts TMT142X
Spare parts TMT142X
B TMT142X-HH Spare parts TMT142X
Spare parts TMT142X
B TMT142X-HK Spare parts TMT142X
Spare parts TMT142X
B TMT162X-HA Spare parts TMT162X
B TMT162X-HC Spare parts TMT162X
B TMT162X-HH Spare parts TMT162X
B TMT162X-HK Spare parts TMT162X
51006845 cable plug
Cable gland NPT 1/2, D4-8.5, IP68
51007995 Mounting Bracket
Mounting bracket SS316L, tube 1,5-3"
71044062 Device Pack
2x screws, 1x sealing CDI-connector
TMT162X-DA Spare parts TMT162X
TMT162X-DB Spare parts TMT162X
TMT162X-DC Spare parts TMT162X
TMT162X-DD Spare parts TMT162X
TMT162A-MA TMT162A Accessories
TMT162A-MB TMT162A Accessories
TMT162A-MD TMT162A Accessories
71111513 ceramic terminal
71111514 ceramic terminal
71386275 Integrable Surge Arrester Module
For subsequent mounting in
field transmitter.
Ensure compatibility.
TMT142- ***iTEMP TMT142, Field Transmitter HART
Temperature transmitter, HART protocol.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanic isolation.
Failure mode: NAMUR NE 43.
Single compartment, NEMA 4X, IP67.
UL listed.
TMT162- Field temperature transmitter TMT162
Temperature transmitter.
Application: RTD, TC, Ohm, mV.
HART, PROFIBUS PA or FOUNDATION
Fieldbus separately available.
Galvanic isolation 2 kV
(sensor input/output).
NEMA 4x, IP67.
Dual compartment.
GL (German Lloyd)Marine (only HART).
UL listed.
A TU211- RTD insert approved, TU211, U.S. Style
Spare part. Flame path Nipple.
Spring loaded.
Pt100 Sensor comply with IEC60751
standard, alpha=0.00385.
B
C
D
E
F
G
J
K
O
1
2
4
5
8
9
A
C
Y
5
6
7
9
A
B
C
D
E
F
G
H
J
K
L
M
Y
2
K
Y
A
B
J
Y
1
B TA30H- junction box TA30H
Retainer for terminal block or head
transmitter optional display.
Design: explosion proof
Cover: screwed, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50#150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
Protection Ex d/XP: IP66/67 (housing).
A1
F1
1
2
B
D
1
2
A
B
TMT31- temperature transmitter TMT31
2-wire temperature transmitter.
Single sensor input.
Application: RTD.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC
presetting failure current low.
Mounting: head form B, DIN EN50446.
CA
A
1
A
1
A1
B2
B3
C1
78
Z2
Z9
TMT71- temperature transmitter TMT71
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC.
CA
A
P
1
A
AA
A1
B2
B3
C1
Z2
TMT72- temperature transmitter TMT72
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification: Pt100, 4-wire, 0... 100oC
CA
A
P
1
A
AA
A1
B2
B3
C1
Z2
TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Presetting failure current high.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
C1
C3
F3
A
2
C
B1
B3
C1
A1
A1
AA
A1
A2
LA
77
TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
C3
F3
A
2
C
B1
B3
C1
TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
C3
F3
A
2
C
B1
B3
C1
TMT162E- Electronic Module TMT162E
Attention: Only 1 piece per position
orderable in offer/order because
item category group ZTA1.
A
A
B
H
I
J
K
K
F TMT162G- Shell TMT162G
A
B
A
B
F
G
K
L
1
A
TID10- temperature transmitter display TID10
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84.
A1
Z2
TMT142E- Electronic Module TMT142E
Attention: Only 1 piece per position
orderable in offer/order because
item category group ZTA1.
A
A
B
C
K
L
M
F TMT142G- Shell TMT142G
Housing TMT142G
A
B
A
B
C
D
1
A
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
TXU10- Instrument debugging package TXU10
for PC-programmable devices
The program sets the connection line for a PC with USB interface
AA
TMT142B- iTEMP temperature transmitter HART TMT142B
2-wire temperature transmitter.
Single universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
Factory setup w/o additional
specification:Pt100, 4-wire, 0... 100oC
presetting failure current low.