CAS40D Dissolved Oxygen Maintenance Kit for Proper Use and Precautions

membrane kit contains membrane and electrolyte capsules for annual demand

membrane kit contains membrane cap and electrolyte to meet annual demand

-2 membrane covers for ammonia, nitrate and potassium
-1 chemical film
-Eccterolet
Nursing suit of Chloride Electrode
-Frosted
-Eccterolet
-2 membrane covers for, nitrate and
-1 compound
Maintenance of the chloride electrode includes
sandpaper
Electrolyte

CAS40D E H dissolved oxygen maintenance kit include electrolyte, O-ring seal, measuring probe, etc. The following are the correct standard measurement methods and precautions for these accessories:
Electrolyte:
Method of use
1. Open the maintenance package and take out the electrolyte
2. Install the electrolyte correctly according to the instructions on the electrode
Note:
1. Ensure the cleanliness of the electrolyte and avoid the generation of impurities and bubbles
2. Follow the instructions for the use of the electrode, and correctly install and replace the electrolyte
3. The electrolyte should be stored in a dry, dark place, avoid high temperature and direct sunlight.

use method
1. Insert the measuring probe into the solution to be tested to ensure that the measuring probe is in full contact with the solution.
2. Press the measurement button and read the measurement result after waiting for stability
3. After the measurement is completed, clean the measuring probe and dry it.
Note:
1. Ensure the cleanliness of the measuring probe and avoid the presence of impurities and dirt
2. Follow the instructions for the use of the electrode and perform the measurement correctly
3. Before measuring, ensure that the measuring probe has been fully warmed up and stable
4. During the measurement process, avoid the measuring probe from strong mechanical vibration or impact
5. Before use, check whether the cable and plug of the measuring probe are in good condition, and replace them in time if they are damaged.
6. Avoid soaking the measuring probe in the solution for a long time, so as not to affect the measurement results
7. Keep the measuring probe dry and clean during storage and transportation.
Through the correct standard measurement methods and precautions, we can ensure that the relevant accessories of the CAS40D E H dissolved oxygen maintenance package can play its due role and improve the accuracy and reliability of the measurement. It is recommended to follow the product manual and the guidance of professional technicians.