Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FDU93 超声波液位计探头

FDU93 超声波液位计探头

超声波液位计探头

Configurable Models 48 models
The FDU93 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 25m (85ft), solids 15m (50ft).
Compare

Continuous / Liquids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2 mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 3 bar abs
(10 psi ... 43 psi)
Main wetted parts UP (unsaturated polyester)
Process connection G / NPT 1"
Blocking distance 0.6 m (2 ft)
Max. measurement distance Liquids: 25 m (85 ft),
Solids: 15 m (50 ft)
Communication Transmitter:
4...20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20 mA output
Components Transmitter:
FMU90, FMU95
Application limits For tank farms scanner:
FMU95

Continuous / Solids

Measuring Principle Ultrasonic
Characteristic / Application Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication 4-wire (HART, PROFIBUS DP)
Accuracy +/- 2mm + 0.17% of measured distance
Ambient temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process temperature -40 °C ... 95 °C
(-40 °F ... 203 °F)
Process pressure / max. overpressure limit 0.7 bar ... 3 bar abs
(10 psi ... 43 psi)
Main wetted parts UP (unsaturated polyester)
Process connection G / NPT 1"
Blocking distance 0.6 m (2 ft)
Max. measurement distance Liquids: 25 m (85 ft),
Solids: 15 m (50 ft)
Communication Transmitter:
4 ... 20 mA HART
PROFIBUS DP
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options Second 4...20mA output
Components Transmitter:
FMU90

The FDU93 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids, is maintenance-free, and can also be used for flow measurement in open channels and weirs. The measured values are unaffected by dielectric constant, density or humidity, and the self-cleaning function of the sensor eliminates the influence of medium adhesion on the measurement. Suitable for hazardous areas; maximum measuring range: liquids 25 m (85 ft), solids 15 m (50 ft).

Benefits
Integrated temperature sensor for time-of-flight correction. Precise measurement even when the temperature changes
Suitable for use in harsh climatic conditions; sensor and transmitter can be installed separately up to 300 m apart
Sensor self-cleaning function reduces adhesion formation
Integrated automatic sensor detection for convenient commissioning with the FMU90 / FMU95 level transmitter
Degree of protection IP68
Non-contact measurement minimizes service requirements
Dust-Ex and gas-Ex approval (ATEX, FM, CSA)

Applications
Suitable for continuous, non-contact level measurement of liquids, pastes, sludge, powders and coarse bulk solids; flow measurement in open channels and weirs. Maximum measuring range: liquids 25 m, solids 15 m; suitable for hazardous areas; other measuring ranges: FDU91/91F: liquids 10 m, solids 5 m; FDU92: liquids 20 m, solids 10 m; FDU95: solids 45 m; FDU96: solids 70 m

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measurement principle video

Source: Endress+Hauserpublic information from the website

Model Name
FDU93-AG1A 超声波液位计探头
FDU93-AG2A 超声波液位计探头
FDU93-AG3A 超声波液位计探头
FDU93-AG4A 超声波液位计探头
FDU93-AG5A 超声波液位计探头
FDU93-AG6A 超声波液位计探头
FDU93-AN1A 超声波液位计探头
FDU93-AN2A 超声波液位计探头
FDU93-AN3A 超声波液位计探头
FDU93-AN4A 超声波液位计探头
FDU93-AN5A 超声波液位计探头
FDU93-AN6A 超声波液位计探头
FDU93-JG1A 超声波液位计探头
FDU93-JG2A 超声波液位计探头
FDU93-JG3A 超声波液位计探头
FDU93-JG4A 超声波液位计探头
FDU93-JG5A 超声波液位计探头
FDU93-JG6A 超声波液位计探头
FDU93-JN1A 超声波液位计探头
FDU93-JN2A 超声波液位计探头
FDU93-JN3A 超声波液位计探头
FDU93-JN4A 超声波液位计探头
FDU93-JN5A 超声波液位计探头
FDU93-JN6A 超声波液位计探头
FDU93-LG1A 超声波液位计探头
FDU93-LG2A 超声波液位计探头
FDU93-LG3A 超声波液位计探头
FDU93-LG4A 超声波液位计探头
FDU93-LG5A 超声波液位计探头
FDU93-LG6A 超声波液位计探头
FDU93-LN1A 超声波液位计探头
FDU93-LN2A 超声波液位计探头
FDU93-LN3A 超声波液位计探头
FDU93-LN4A 超声波液位计探头
FDU93-LN5A 超声波液位计探头
FDU93-LN6A 超声波液位计探头
FDU93-RG1A 超声波液位计探头
FDU93-RG2A 超声波液位计探头
FDU93-RG3A 超声波液位计探头
FDU93-RG4A 超声波液位计探头
FDU93-RG5A 超声波液位计探头
FDU93-RG6A 超声波液位计探头
FDU93-RN1A 超声波液位计探头
FDU93-RN2A 超声波液位计探头
FDU93-RN3A 超声波液位计探头
FDU93-RN4A 超声波液位计探头
FDU93-RN5A 超声波液位计探头
FDU93-RN6A 超声波液位计探头
市政污水处理

市政污水处理污水处理厂 · 超声波应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 超声波应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 超声波应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 超声波应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对超声波的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的超声波,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。