Technical Data
ComparepH
| Measuring Principle | ISFET |
| Application | For applications requiring high accuracy in blocking media or high content of organic solvents |
| Characteristic | Digital, sterilizable and autoclavable pH electrodes for hygienic production processes with KCl vessel for measuring in media with low conductivity |
| Reference | Liquid KCl |
| Measuring range | pH 0 to 14 |
| Material | Sensor shaft: PEEK Sealings: FFKM Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225 and 360 mm (4.72, 8.86 and 14.17 inch) |
| Process temperature | -15 to 135 °C (5 to 275 °F) |
| Process pressure | Max. 11 bar abs at 100 °C (max. 160 psi at 212 °F) |
| Temperature sensor | Pt1000 |
| Ex certification | With the following approvals for use in potentially explosive areas of Zone 0, Zone 1 and Zone 2: ATEX, IECEx, CSA C / US, NEPSI, JPN Ex, INMETRO, UKCA and Korea Ex |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology |
| Ingress protection | IP 68 |
Field of application
Memosens CPS47E is the high performer with liquid KCl reference for media with low conductivity or high organic load. It measures accurately even in applications with fast-changing media. Its unbreakable shaft ensures best product safety. Thanks to Memosens 2.0 digital technology, the pH sensor resists moisture and enables lab calibration, increasing process safety and simplifying operation. Its extended storage of calibration and process data provides a perfect basis for predictive maintenance.
Media with a high amount of organic solvents or very low conductivities:
Chemical industry, measurement of media prone to clogging
Power plants, e.g. boiler feed water
Life sciences, e.g. water for injection
With all relevant approvals for hygienic applications such as EHEDG, 3A, EU1935/2004, USP 87/88
Benefits
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Unbreakable: Non-glass PEEK body ensures highest product safety where glass breakage is intolerable.
Resistant to poisoning: Constant refilling of KCl bridge electrolyte and separate reference lead prevent poisoning ions from entering the electrode.
The sensor is suitable for autoclaving and sterilization with hot steam offering long-term stable measurement.
Low maintenance: ISFET technology is insensitive to temperature changes enabling long calibration intervals
Maximum process safety: Thanks to non-contact, inductive signal transmission, problems with moisture are a thing of the past.
Reduced operating costs: Laboratory calibration and fast sensor exchange on-site minimize process downtime and extend sensor lifetime
pH:
| Measuring Principle | ISFET | |
| Application | For applications requiring high accuracy in blocking media or high content of organic solvents | |
| Characteristic | Digital, sterilizable and autoclavable pH electrodes for hygienic production processes with KCl vessel for measuring in media with low conductivity | |
| Reference | Liquid KCl | |
| Measuring range | pH 0 to 14 | |
| Material | Sensor shaft: PEEK Sealings: FFKM Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
|
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225 and 360 mm (4.72, 8.86 and 14.17 inch) |
|
| Process temperature | -15 to 135 °C (5 to 275 °F) | |
| Process pressure | Max. 11 bar abs at 100 °C (max. 160 psi at 212 °F) | |
| Temperature sensor | Pt1000 | |
| Ex certification | With the following approvals for use in potentially explosive areas of Zone 0, Zone 1 and Zone 2: ATEX, IECEx, CSA C / US, NEPSI, JPN Ex, INMETRO, UKCA and Korea Ex | |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology | |
| Ingress protection | IP 68 | |
Related Models
| Model | Name |
|---|---|
| CPS47E-AA6BSB2 | 非玻璃PH电极 |
| CPS47E-AA6BSB5 | 非玻璃PH电极 |
| CPS47E-NA6BSB2 | 非玻璃PH电极 |
Case Studies
市政污水处理污水处理厂 · PH应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · PH应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · PH应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · PH应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。