电子振动式限位检测
The Nivotester FTL825 directly powers the Liquiphant fail-safe FTL8x vibronic level switch via a two-core cable, while analyzing the Liquiphant current value (independent 4-20 mA) and returning the switch signal. The input signal of the Nivotester FTL825 is electrically isolated from the output and the power supply; the system functional safety reaches SIL3, and redundant or diverse systems are not recommended or cannot be used.
Benefits
SIL3 functional safety features: internal dual-channel design, permanent self-monitoring, online monitoring of the connection to the sensor, permanent monitoring of the Liquiphant fail-safe limit switch
LIVE signal permanently visualized
Advanced fault detection functions and error message display
Verification of the entire measuring system, including the control and signaling devices in the loop, via the verification test key or remote control
Integrated locking function (self-holding)
Four switch outputs (individually evaluable): two as level safety contacts in accordance with the quiescent-current principle for output signal redundancy; one signal contact (e.g. lamp), one fault-signal changeover contact
Proof test: proof test intervals of up to 12 years
Applications
Fail-safe limit detection switch, rail-mountable
Ambient temperature: -20 ~ +60°C (-4 ~ +140°F)
International explosion-protection approval, overflow protection WHG
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Vibration Liquids |
| Characteristic / Application | FailSafe level transmitter point level. Top hat rail mounting Connection to FTL80/81/85 Permanent self-monitoring,LIVE-Signal. |
| Specialities | SIL 3 according to IEC61508. |
| Supply / Communication | 85 - 253 VAC/DC 20 - 30 VAC/20-60VDC |
| Ambient temperature | –20 to +60 °C (–4 to +140 °F) |
| Communication | 2x SPST safety contact point level 1x SPST signal contact 1X SPDT fault contact |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI |
| Safety approvals | Overfill protection WHG Leakage Detection |
| Marine approval | GL/ ABS/ LR/ BV/ DNV |
Case Studies
市政污水处理污水处理厂 · 音叉应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对音叉的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 音叉应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对音叉的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 音叉应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对音叉的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 音叉应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对音叉的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。