适配器
Technical Data
CompareWireless components
| Measuring Principle | WirelessHART |
| Function | Intelligent WirelessHART and/or Bluetooth® interface module for easy and fast connection to HART devices |
| Certification | Non-hazardous area, ATEX, IEC Ex |
| Input | One point-to-point with HART device |
| Output | WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft) |
| Auxiliary power supply / Loop power supply | Loop-powered 4 to 20 mA |
| Dimensions (wxhxd) | W x H x D: 146 mm x 42 mm x 42 mm (dimensions in mm 25.4 = 1 inch) |
| Software | Internal software for reading data from HART field devices and communicating over WirelessHART and/or Bluetooth® |
| Operation | Integral via DIP-switches, Cell Phone configuration via SmartBlue App and Bluetooth®, Field Xpert configuration via Bluetooth® or HART-modem, PC configuration via FieldCare and HART-modem, PC configuration via FieldCare and WirelessHART Gateway |
| Operating Voltage | 24 V DC (min. 4 V DC, max. 30 V DC): min. 3.6 mA loop current required for start-up Voltage drop if internal HART communication resistor is deactivated: 3.2 V in operation, < 3.8 V at start-up Voltage drop if internal HART communication resistor is activated (270 Ohm): < 4.2 V at 3.6 mA loop current, < 9.3 V at 22.5 mA loop current |
FieldPort SWA50 connects HART field devices and reliably converts the HART signal into an encrypted Bluetooth® or WirelessHART signal. Use the Endress+Hauser SmartBlue app or Endress+Hauser Field Xpert to configure FieldPort SWA50 and view the measured values and the status of the connected HART field devices. HART field devices can be connected to the Netilion cloud ecosystem via FieldPort SWA50 and FieldEdge.
Benefits
Connect FieldPort SWA50 to reliably transmit process measured values via encrypted Bluetooth® or WirelessHART communication
Easily upgrade all two-wire or four-wire HART field devices
All HART field devices can be easily connected to the Netilion cloud ecosystem
The adapter is loop-powered and does not interfere with the process signal
Easily query diagnostic information of the connected HART field devices via the wireless connection
Application
FieldPort can easily upgrade all two-wire or four-wire HART field devices and can be installed in hazardous and non-hazardous areas. FieldPort SWA50 is equipped with a stainless steel housing, is robust and durable, and can be used in demanding operating conditions.
E+H product model configuration tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below, up to three products
Technical documentation
Technical specifications
Documents / Manuals / Software
Accessories / Spare parts
Source: Endress+Hauser public website information
Case Studies
市政污水处理污水处理厂 · 网关和modem应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对网关和modem的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的网关和modem,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 网关和modem应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对网关和modem的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的网关和modem,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 网关和modem应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对网关和modem的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的网关和modem,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 网关和modem应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对网关和modem的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的网关和modem,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。