CCS53E Digital Total Chlorine Sensor

CCS53E Digital Total Chlorine Sensor

数字式总氯传感器

Configurable Models 29 models
CCS53E digital disinfectant sensor is widely used in wastewater treatment and various industry utility applications
Compare

Disinfection

Measuring Principle Total chlorine
Application Wastewater treatment plants, disinfection monitoring and control in wastewater outlet, reuse of outlet water
utilities of all industries
drinkingwater to regulate disinfection
all disinfection measuring points
swimming pool with efficient disinfection
Food and Beverage, cleaning water or zero chlorine applications for reverse osmosis,
Characteristic Amperometric measurement of total chlorine
Measuring range 0 to 5 mg/l total chlorine or
0 to 20 mg/l total chlorine
Measuring method Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent
Design Closed amperometric 2-electrode measuring cell with PET membrane
Material Sensor shaft: POM
Membrane: PET/PVDF
Mebrane cap: PVDF
Dimension Diameter: 25 mm (0.98 in)
Length: 161 mm (6.34 in)
Process temperature 0 to 55 °C , non-freezing
(32 to 130 °F)
Process pressure 1 bar relative (14,5 psi relativ)
Max. 2 bar (max. 29 psi)
Temperature sensor 10k NTC integrated (Memosens)
Connection Inductive, digital connection head with Memosens 2.0

Total chlorine is the sum of free chlorine and combined chlorine and is an indicator of the residual disinfectant concentration in discharged wastewater and process water. The Memosens CCS53E continuously outputs total chlorine measured values, even after a period in a chlorine-free environment. It can therefore measure in a "zero" chlorine environment, i.e. chlorine-free processes. The sensor uses Memosens 2.0 digital technology, guaranteeing high process safety and data integrity with simple operation. It supports predictive maintenance strategies.

Advantages
Even after chlorine-free processes, the sensor responds quickly and does not become deactivated. Continuous measurement helps to respond quickly to process changes and ensure compliance.

Compared to the colorimetric measuring principle, membrane-covered sensors have lower maintenance requirements, significantly reducing operating costs.

Long-term trouble-free operation: pre-calibrated sensors are plug-and-play and easy to replace. In addition, the Memosens 2.0 digital sensor has a shorter polarization time.

Used with Liquiline multiparameter transmitters to simultaneously measure other relevant water analysis parameters such as pH and ORP.

Wide measuring range and versatile applications: from zero chlorine and trace chlorine to applications with chlorine concentrations up to 20 mg/l.

Field of application
The Memosens CCS53E total chlorine sensor measures reliably:

Wastewater treatment plants: monitoring the quality of discharged wastewater to ensure safe recycling and reuse

Utility water in various industries: detecting the total chlorine concentration to avoid harmful consequences (e.g. in cooling towers)

Food and beverage industry: ensures hygienic bottle separation and filling, guarantees high product quality (e.g. rinse water), and protects the membrane in reverse osmosis systems

Drinking water: ensures adequate disinfection and prevents overdosing of disinfectant

Swimming pool water: detecting impurities

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

 

Source:Endress+Hauserpublic information from the website

Model Name
CCS53E-AA11ADNA 数字式总氯传感器
CCS53E-AA11ADNB 数字式总氯传感器
CCS53E-AA11ADNC 数字式总氯传感器
CCS53E-AA11ADND 数字式总氯传感器
CCS53E-AA11BFN0 数字式总氯传感器
CCS53E-AA11BFNA 数字式总氯传感器
CCS53E-AA11BFNB 数字式总氯传感器
CCS53E-AA11BFNC 数字式总氯传感器
CCS53E-AA11BFND 数字式总氯传感器
CCS53E-CD11ADN0 数字式总氯传感器
CCS53E-CD11ADNA 数字式总氯传感器
CCS53E-CD11ADNB 数字式总氯传感器
CCS53E-CD11ADNC 数字式总氯传感器
CCS53E-CD11ADND 数字式总氯传感器
CCS53E-CD11BFN0 数字式总氯传感器
CCS53E-CD11BFNA 数字式总氯传感器
CCS53E-CD11BFNB 数字式总氯传感器
CCS53E-CD11BFNC 数字式总氯传感器
CCS53E-CD11BFND 数字式总氯传感器
CCS53E-UR11ADN0 数字式总氯传感器
CCS53E-UR11ADNA 数字式总氯传感器
CCS53E-UR11ADNB 数字式总氯传感器
CCS53E-UR11ADNC 数字式总氯传感器
CCS53E-UR11ADND 数字式总氯传感器
CCS53E-UR11BFN0 数字式总氯传感器
CCS53E-UR11BFNA 数字式总氯传感器
CCS53E-UR11BFNB 数字式总氯传感器
CCS53E-UR11BFNC 数字式总氯传感器
CCS53E-UR11BFND 数字式总氯传感器
市政污水处理

市政污水处理污水处理厂 · 消毒应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 消毒应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 消毒应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 消毒应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对消毒的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的消毒,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。