枕式组件
Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Characteristic | Life Sciences, Oil & Gas, Chemical Industries |
| Design | flow assembly with small bore from 5mm ... 45mm corresponding the Clamp Diameters for mounting 1Memosens CLS82D and or 1 pH electrode (CPS71D-TU) |
| Material | Holder: stainless steel or PVDF Sealings: EPDM, Kalrez, Viton, Teflon-coated Viton (all FDA compliant) |
| Dimension | flange spacing 82,55 mm, 3;25 |
| Process temperature | max.130°C 266°F |
| Process pressure | Stainless steel: max. 16 bar; PVDF: max 4 bar |
| Connection | Clamp 0,25" ... 2" |
| Certificates, declarations and approvals | Material certification 3.1 EN 10204 Surface roughness Ra < 0.38 µm. |
pH
| Measuring Principle | Potentiometric |
| Application | Life Sciences, Oil & Gas, Chemical Industries |
| Installation | flow assembly,with Clamp 0,25" ... 2" |
| Characteristic | pipe mounting |
| Design | flow assembly with small bore from 5mm ... 45mm corresponding the Clamp Diameters for mounting 1 pH electrode (CPS71D-TU) and 1Memosens CLS82D |
| Material | Holder: stainless steel or PVDF Sealings: EPDM, Kalrez, Viton, Teflon-coated Viton (all FDA compliant) |
| Dimension | flange spacing 82,55 mm, 3;25" |
| Process temperature | max.130°C 266°F |
| Process pressure | Stainless steel: max. 16 bar; PVDF: max 4 bar |
| Connection | Clamp 0,25" ... 2" |
| Certificates, declarations and approvals | Material certification 3.1 EN 10204 Surface roughness Ra < 0.38 µm. |
Flow assembly
CYA680
Assembly for the life sciences and chemical industries
Benefits
Fast measured values with low volume optimize product yield
High product safety: assembly suitable for cleaning in place (CIP) and sterilization in place (SIP)
Compliance with strict life sciences regulations: biocompatibility certified according to USP Class VI, FDA-certified seals and hygienic electropolished surface Ra=0.38 μm (15 μinch)
Even suitable for corrosive media with the PVDF version
Application areas
The CYA680 flow assembly is a simple solution for pH and conductivity measurement in pipelines of hygienic and sterile applications. It is designed for in-line cleaning and sterilization, ideally suited to small-diameter pipelines, providing maximum safety for your high-quality product. For perfect performance in corrosive and aggressive media, the CYA680 is available in a PVDF version.
The CYA680 flow assembly is used in combination with 12 mm sensors, e.g.
pH measurement
Conductivity measurement
It is particularly suitable for all applications requiring small diameters, e.g.:
Chromatography
Filtration
Reverse osmosis
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the product order codes to be compared in the input boxes below; a maximum of three products can be compared
Technical documentation
Technical specifications
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauser website public information
Case Studies
市政污水处理污水处理厂 · 支架应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 支架应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 支架应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 支架应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。