多点温度计
Technical Data
CompareThermometer
| Measuring Principle | Thermocouple |
| Characteristic / Application | metric style imperial style easy-to-use suitable for hazardous areas compression fitting as process connection without neck light chemical processes |
| Thermowell / protection tube | without (not intended to use with thermowell) |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 6,0 mm (0,24'') 3,2 mm (0,126") 8,0 mm (0,31") 9,5 mm (0,37") 6,35 mm (1/4") |
| Max. immersion length on request | up to 13.000,00 mm (511,81'') |
| Material protection tube/ thermowell | 1.4401 (316) 1.4435 (316L) 1.4571 (316Ti) 1.4541 (321) 1.4550 (347) Alloy 600 (2.4816) |
| Process connection | Compression fitting threaded 1/4" Compression fitting threaded 1/2" Compression fitting threaded 3/4" Compression fitting threaded 1" Flange as an accessory |
| Tip shape | straight |
| Operating temperature range | Type K: max. 920 °C (max. 1.688 °F) Type J: max. 440 °C (max. 824 °F) Type N: max. 920 °C (max. 1.688 °F) Type E: max. 510 °C (max. 950 °F) |
| Max. process pressure (static) | at 20 °C: 90 bar (1305 psi) |
| Accuracy | class 2 acc. to IEC 60584 ASTM E230 and ANSI MC 96.1 |
| Response time | t50 = 3 s t90 = 9 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX Ex ia IECEx Ex ia IECEx ATEX Ex ia NEPSI Ex ia UKCA Ex ia EAC Ex ia UL CSA |
| Certification | SIL (transmitter only) |
iTHERM MultiSens Slim TMS21
Multipoint thermometer
Low-invasive, flexible TC temperature profile solution for petrochemical and chemical applications
Benefits
Large number of measuring points with a small diameter
Low-invasive temperature profile probe
Easy installation and wiring
Application areas
Designed for applications where small probe dimensions and low weight are required. The TMS21 is versatile and can be highly customized. It monitors the temperature at a large number of points along a production line using just one process connection. It consists of several small-diameter thermocouples protected by one monolithic primary tube thermowell. Two different product configurations are available, with or without a flexible upper thermowell (for axial centering).
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the product order codes to be compared in the input boxes below; a maximum of three products can be compared
Technical documentation
Technical specifications
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauser website public information
Case Studies
市政污水处理污水处理厂 · 热电偶应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电偶的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 热电偶应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电偶的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 热电偶应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电偶的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 热电偶应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电偶的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。