PH电缆
Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Ingress protection | IP65 |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Connection | IP65 |
pH
| Measuring Principle | Potentiometric |
| Application | Laboratory Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
| Material | PEEK / TPE |
| Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
| Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
| Ingress protection | IP 65 |
The CYK20 is a flexible data cable that reliably connects Memosens sensors to the Memobase Plus sensor software and the Liquiline To Go portable transmitter. It provides a fully waterproof connection with an inductive coupling, free of contact corrosion and easy to use. It enables safe and reliable signal transmission without contact corrosion or potential interference.
Advantages
Unique design for laboratory applications: flexible, easy to operate, fast connection of sensors for various parameters
Non-contact inductive digital signal transmission for the highest process safety: no contact corrosion, fully waterproof, no potential interference
Hazardous area approval
Areas of application
The CYK20 is a Memosens data cable used in laboratories in all industries. Suitable for the following parameters:
pH/ORP
Dissolved oxygen (membrane method)
Conductive conductivity
Disinfection
All electrodes with Memosens plug can be connected to:
Memobase Plus CYZ71D software (Memolink)
Liquiline To Go CYM290/CYM291 portable transmitter
International explosion protection approvals such as ATEX and IECEx; the cable can be used in hazardous areas.
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measuring principle video
Related Models
| Model | Name |
|---|---|
| CYK20-AAB1C2 | pH电缆 |
| CYK20-AAB2C2 | pH电缆 |
Case Studies
市政污水处理污水处理厂 · EH-Lab应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对EH-Lab的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-Lab,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · EH-Lab应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对EH-Lab的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-Lab,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · EH-Lab应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对EH-Lab的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-Lab,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · EH-Lab应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对EH-Lab的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的EH-Lab,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。