模块式铂电阻()温度计
A highly modular, robust thermometer suitable for applications in almost all industries. Devices with an optional head-mounted transmitter are compatible with all common communication protocols, ready for immediate use and, compared with directly wired sensors, improve measurement accuracy and reliability. A wide range of process connections, dimensions and materials provide application flexibility.
Advantages
Modular design with a standard connection head compliant with DIN EN 50446 and customer-specific immersion length for high flexibility
High insert compatibility, designed to DIN 43772
Short tapered/conical tip for faster response time
Protection types for use in hazardous areas: intrinsically safe (Ex ia), non-sparking (Ex nA)
Easy selection of head transmitter: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus
Marine approval
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style modular temperature assembly universal range of application suitable for hazardous areas threaded process connection without neck incl. thermowell / protection tube (metal) can be used with StrongSens insert |
| Thermowell / protection tube | welded protection tube |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 8,0 mm (0,31") 9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'') 14,0 mm (0,55") 15,0 mm (0,59") |
| Max. immersion length on request | up to 10.000,00 mm (393,70'') |
| Material protection tube/ thermowell | 1.4401 (316) 1.4404 (316L) 1.4571 (316Ti) |
| Optional coating | Not defined |
| Process connection | male thread: G3/8" G1/2" G3/4" NPT1/2" NPT3/4" M20x1.5 |
| Tip shape | straight reduced tapered |
| Surface roughness Ra | Not defined |
| Operating temperature range | PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) |
| Max. process pressure (static) | at 20 °C: 75 bar (1088 psi) |
| Accuracy | class A acc. to IEC 60751 class AA acc. to IEC 60751 |
| Response time | depending on configuration |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6 ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6 ATEX IECEx II1/2D Ex ta/tb IIIC Da/Db ATEX II1G Ex ia IIC T6 ATEX II 3 G Ex nA IIC T6, II3D NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450 IECEx Ex ia IIC T6 Ga/Gb EAC Ex ia IIC T6 Ga + DIP NEPSI Ex nA IIC T6 |
| Certification | Gost Metrology SIL (transmitter only) Marine approval |
Related Models
| Model | Name |
|---|---|
| TR11-AAACASX43000 | 模块式铂电阻(RTD)温度计 |
| TR11-ABBCASXKT000 | 模块式铂电阻(RTD)温度计 |
Case Studies
市政污水处理污水处理厂 · 热电阻应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 热电阻应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 热电阻应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 热电阻应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电阻的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。







