温度变送器
Technical Data
CompareTemperature transmitters
| Measuring Principle | |
| Input | 1 x RTD, TC, Ohm, mV |
| Output | 1 x analog 4...20 mA |
| Auxiliary power supply | 11,5...35 V DC (standard-version) 11,5...30 V DC (Ex-version) |
| Communication | HART-protocol |
| Installation | Terminal head form B |
| Accuracy | (Pt100, -50...200 °C) <= 0,2 K (Pt100, -58...392 °F) <= 0,4 °F |
| Galvanic isolation | yes |
| Certification | UL Ex IS UL Ex NI GL marine approval GOST Ex i FM IS,NI,Class I,Div.1+2,Group ABCD CSA IS,NI,Class I,Div.1+2,Group ABCD ATEX II1G Ex ia IIC T4/T5/T6 ATEX II3G Ex nA IIC T4/T5/T6 ATEX II3D ATEX II1G Ex ia IIC T6, II3D ATEX II3G Ex nA IIC T6, II3D FM+CSA IS,NI,Class I,Div.1+2,Group ABCD CSA General Purpose IECEx Ex ia IIC T6/T5/T4 ATEX IECEx II1G Ex ia IIC T6 Ga EAC Ex ia IIC T6 Ga GL (German Lloyd) |
This configurable transmitter offers outstanding reliability, accuracy and long-term stability and can be used in critical processes in all industries. It not only transmits converted signals from resistance thermometers (RTD) and thermocouples (TC), but can also transmit resistance and voltage signals using the HART® communication protocol. The intrinsically safe instrument can be installed in hazardous Zone 1 and can be operated, displayed and maintained quickly and easily using PC operating software.
Advantages
Operation via handheld or PC
High-precision measurement over the entire ambient temperature range
Fault signal on sensor wire break or short circuit, with preset values in accordance with NAMUR NE 43
Electromagnetic compatibility (EMC) in accordance with NAMUR NE 21, CE approval
Explosion protection approvals: ATEX Ex ia and Zone 22 dust explosion protection in accordance with EN 50281-1, FM IS and CSA IS
Galvanic isolation
Meets SIL2 requirements, marine approval
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Related Models
| Model | Name |
|---|---|
| TMT182-1AAAA | 温度变送器 |
| TMT182-1BAAA | 温度变送器 |
| TMT182-1E1AA | 温度变送器 |
| TMT182-AAAAA | 温度变送器 |
| TMT182-ABAAA | 温度变送器 |
| TMT182-B31AA | 温度变送器 |
| TMT182-B31BA | 温度变送器 |
| TMT182-B41BA | 温度变送器 |
| TMT182-BBAAA | 温度变送器 |
| TMT182-BBAAAZ | 温度变送器 |
Case Studies
市政污水处理污水处理厂 · 温度变送器应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 温度变送器应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 温度变送器应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 温度变送器应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。