Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

TMT182 E+H temperature transmitter

TMT182 E+H temperature transmitter

温度变送器

Configurable Models 10 models
Common model: Non explosion proof TMT182-ABAAA, explosion proof: TMT182-BBAAA TMT182 is equipped with HART communication, which allows for online parameter modification, equivalent to a model that can be modified to any parameter required by the customer. If the customer wants to modify it themselves, they need to purchase the FXA195-G1 tool separately.
Compare

Temperature transmitters

Measuring Principle
Input 1 x RTD, TC, Ohm, mV
Output 1 x analog 4...20 mA
Auxiliary power supply 11,5...35 V DC (standard-version)
11,5...30 V DC (Ex-version)
Communication HART-protocol
Installation Terminal head form B
Accuracy (Pt100, -50...200 °C) <= 0,2 K
(Pt100, -58...392 °F) <= 0,4 °F
Galvanic isolation yes
Certification UL Ex IS
UL Ex NI
GL marine approval
GOST Ex i
FM IS,NI,Class I,Div.1+2,Group ABCD
CSA IS,NI,Class I,Div.1+2,Group ABCD
ATEX II1G Ex ia IIC T4/T5/T6
ATEX II3G Ex nA IIC T4/T5/T6
ATEX II3D
ATEX II1G Ex ia IIC T6, II3D
ATEX II3G Ex nA IIC T6, II3D
FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
CSA General Purpose
IECEx Ex ia IIC T6/T5/T4
ATEX IECEx II1G Ex ia IIC T6 Ga
EAC Ex ia IIC T6 Ga
GL (German Lloyd)

This configurable transmitter offers outstanding reliability, accuracy and long-term stability and can be used in critical processes in all industries. It not only transmits converted signals from resistance thermometers (RTD) and thermocouples (TC), but can also transmit resistance and voltage signals using the HART® communication protocol. The intrinsically safe instrument can be installed in hazardous Zone 1 and can be operated, displayed and maintained quickly and easily using PC operating software.

 

Advantages

Operation via handheld or PC

High-precision measurement over the entire ambient temperature range

Fault signal on sensor wire break or short circuit, with preset values in accordance with NAMUR NE 43

Electromagnetic compatibility (EMC) in accordance with NAMUR NE 21, CE approval

Explosion protection approvals: ATEX Ex ia and Zone 22 dust explosion protection in accordance with EN 50281-1, FM IS and CSA IS

Galvanic isolation

Meets SIL2 requirements, marine approval

 

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Model Name
TMT182-1AAAA 温度变送器
TMT182-1BAAA 温度变送器
TMT182-1E1AA 温度变送器
TMT182-AAAAA 温度变送器
TMT182-ABAAA 温度变送器
TMT182-B31AA 温度变送器
TMT182-B31BA 温度变送器
TMT182-B41BA 温度变送器
TMT182-BBAAA 温度变送器
TMT182-BBAAAZ 温度变送器
市政污水处理

市政污水处理污水处理厂 · 温度变送器应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 温度变送器应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 温度变送器应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 温度变送器应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。