Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

PMD55 differential pressure transmitter

PMD55 differential pressure transmitter

差压变送器

Configurable Models 19 models
PMD55 is a commonly used E+H differential pressure transmitter, suitable for most application scenarios and cost-effective.
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply / Communication 4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
Accuracy 0,1%
"PLATINUM" 0,075%
Long term stability 0,05% of URL/year
0,125% of URL/5 years
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -40 °C...85 °C
(-40 °F...185 °F)
Process pressure / max. overpressure limit 160 bar
Pressure measuring range 10mbar...40bar
(0.15...580psi)
Main wetted parts 316L
Process connection 1/4-18 NPT
Communication 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
AD2000
Options 4-line digital display
Aluminium housing
Successor PMD55B
Application limits Measuring cell:
Metal welded

Gas

Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error 0,1%
"PLATINUM" 0,075%
Max. process pressure 10mbar...40bar
(0.15...580psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
Digital communication HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety SIL
Material certificates NACE MR0103
NACE MR0175
EN10204-3.1

Liquids

Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error 0,1%
"PLATINUM" 0,075%
Max. process pressure 10 mbar...40 bar
(0.15...580 psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
Digital communication HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety SIL
Material certificates NACE MR0103
NACE MR0175
EN10204-3.1

Pressure

Measuring Principle Differential pressure
Characteristic Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply voltage 4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard 0.1%
Platinum 0.075%
Long term stability 0.05% of URL/ year
0.13% of URL/ 5 years
0.23% of URL/ 10 years
Process temperature -40°C...+85°C
(-40°F...+185°F)
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Measuring cell 10 mbar...40 bar
(0.15...580 psi)
Smallest calibratable span 10 mbar (0.15 psi)
Max. Turn down 20:1
Max. overpressure limit on one side:
160 bar
(2300 psi)
Process connection 1/4-18 NPT
Material process membrane 316L, AlloyC,
Material gasket Viton, PTFE, EPDM, NBR
Fill fluid Silicone oil
Inert oil
Material housing Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals NACE MR0175
EN10204-3.1
Successor PMD55B

Steam

Measuring Principle Differential pressure
Product headline Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error 0,1%
"PLATINUM" 0,075%
Max. process pressure 10mbar...40bar
(0.15...580psi)
Medium temperature range Temperature gradient from pressure piping
Display/Operation Option
Outputs 4...20mA HART
Digital communication HART
Hazardous area approvals ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safety SIL
Material certificates NACE MR0103
NACE MR0175
EN10204-3.1

The Deltabar PMD55 differential pressure transmitter uses a piezoresistive sensor and a welded metal diaphragm and is mainly used for differential pressure measurement of liquids, steam and gases in the process industry or the environmental protection industry. The measuring range is adjustable, and fast setup simplifies commissioning, reduces costs and saves time. It complies with IEC61508/IEC61511 and meets SIL3 safety requirements.

Advantages

Reference accuracy: 0.1%, Platinum version: up to ±0.075%

Turndown ratio: 100:1 or higher

One-piece transmitter

Fast commissioning using DIP switches

Simple, safe menu-guided operation: - via the on-site display module: - via 4...20 mA HART - via PROFIBUS PA, - via FF FOUNDATION Fieldbus

Modular continuous measurement of differential pressure, static pressure and pressure (Deltabar M - Deltapilot M, Cerabar M), e.g. - replaceable display, - universal electronics for pressure and differential pressure measurement

Wide range of approvals for international use

Application areas

For liquid level, volume or mass measurement, differential pressure monitoring of filters and pumps, and, in combination with primary elements, measurement of gas, steam and liquid flow (volume flow or mass flow)

Process connection: thread

Process temperature: -40... 85°C (-40... 185°F)

Measuring range: 0.5mbar ... 40bar (0.0072 ... 600psi)

Accuracy: ±0.1%, "Platinum" ±0.075% (optional)

International explosion protection approval, SIL

 

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

   

Orifice plate flowmeter measuring principle video

   

Pitot tube measuring principle video

Source:Endress+Hauserpublic information from the website

Model Name
PMD55-AA21BA27CGCHA4A1A+AK 差压变送器
PMD55-AA21BA67DGCHAJA1A+AK 差压变送器
PMD55-AA21BA67DGCHAJA2A+AA 差压变送器
PMD55-AA21BA67DGJHAJA1A+AK 差压变送器
PMD55-AA21BA67DGJHAJA1AABPDZ1 差压变送器
PMD55-AA21BA67HGCHAJA1A+AK 差压变送器
PMD55-AA21BA67LGCHAJA1A+AK 差压变送器
PMD55-AA21BB67DGJHA4A1APBZ1 差压变送器
PMD55-AA22AA67FGJHAJA1J 差压变送器
PMD55-BA21BA27CGCHAJA1A+AK 差压变送器
PMD55-BA21BA67GGCHAJA1A+AK 差压变送器
PMD55-BA21BA67HGCHAJA1A+AK 差压变送器
PMD55-BA21BA67LGCHAJA1A+AK 差压变送器
PMD55-BC21BB67LGCHAJA1A+AK 差压变送器
PMD55-BD22AB77LGJHAJA1J+P5 差压变送器
PMD55-NA21BA67GGCHAJA1A+AK 差压变送器
PMD55-NA21BA67HGCHAJA1A+AK 差压变送器
PMD55-NA21BA67LGCHAJA1A+AK 差压变送器
PMD55-NA21BB67HGCHAJA1A+AK 差压变送器
市政污水处理

市政污水处理污水处理厂 · 差压测量应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对差压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 差压测量应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对差压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 差压测量应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对差压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 差压测量应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对差压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的差压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。