The modular industrial RTD or TC thermometer iTHERM ModuLine TM152 is complete with barstock thermowell or to be used with onsite thermowell. It is suitable for every application, from basic functionality to high-end performance in the chemical, oil & gas and power & energy industries.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application imperial style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or iTHERM QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with iTHERM StrongSens
Thermowell / protection tube barstock (drilled) or to be used with thermowell
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 5/8" (15.88 mm)
3/4" (19.05 mm)
7/8" (22.2 mm)
1" (25.4 mm)
1.050" (26.7 mm)
1-1/16" (27 mm)
1-1/8" (28.58 mm)
1-1/4" (31.75 mm)
1.315" (33.4 mm)
1-3/8" (34.93 mm)
1-1/2" (38.1 mm)
1.660" (42.16 mm)
1.900" (48.26 mm)
Max. immersion length on request 84"
Material protection tube/ thermowell 316/316L
304/304L
Alloy600
AlloyC276
A182 F22
A182 F11
A182 F91
A105
Duplex
Optional coating PTFE coated
Tantalum sleeve
Process connection Male thread:
G1/2", G3/4"
NPT1/2", NPT3/4", NPT 1", NPT 1-1/4", NPT 1-1/2"
Innen-Gewinde:
NPT1/2"
Flansche:
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1" 600 RF
ASME 1" 900/1500 RF
ASME 1 1/2" 150 RF
ASME 1 1/2" 300 RF
ASME 1 1/2" 600 RF
ASME 1 1/2" 900/1500 RF
ASME 2" 150 RF
ASME 2" 300 RF
ASME 2" 600 RF
zum Einschweißen:
NPS 3/4" (26.7 mm)
NPS 1" (33.4 mm)
NPS 1-1/4" (42.2 mm)
NPS 1-1/2" (48.3 mm)
1-3/8" (34.92 mm)
Tip shape straight
tapered
stepped
Surface roughness Ra 0,76 μm (30 μin.)
1,6 μm (63,0 μin.)
Operating temperature range PT100 TF iTHERM StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 TF iTHERM QuickSens:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 basic TF:
-50 °C ...200 °C
(-58 °F ...392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration up to 500 bar
Accuracy Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response time depending on configuration
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX Ex ec
ATEX IECEx Ex ia
CSA C/US IS, NI, XP, DIP
INMETRO Ex ia
Certification SIL (Transmitter), CRN

iTHERM ModuLine TM152 modular industrial thermometer, RTD or thermocouple thermometer (imperial instrument) with integrated bar stock thermowell, widely used in industry

Advantages

  • Easy maintenance and recalibration of the thermometer (sensor replacement without interrupting the process)

  • Secondary sealing technology:Second process seal with fault indication function, providing useful information on the device health status

  • iTHERM QuickSens:Fast response with a response time of only 1.5 seconds, helping to optimize process control

  • iTHERM StrongSens:Superior vibration resistance (> 60g), ensuring high plant safety

  • iTHERM QuickNeck:Convenient removal of the thermometer without additional tools for recalibration of the device, saving cost and time

  • Numerous international certifications:Explosion protection certifications ATEX, IECEx, CSA and INMETRO; SIL functional safety certification

  • The iTEMP temperature transmitter supportsall common communication protocols, and can beoptionally equipped with Bluetooth® wireless connection

 

Field of application

The modular industrial RTD or thermocouple thermometer iTHERM ModuLine TM152 comes with an integrated bar stock thermowell or is used with an existing thermowell. It is very versatile, ranging from versions with basic functions to high-performance versions for the chemical, oil and gas, and power and energy industries.

  • Wide range of applications

  • Measuring range: –200...+1,100°C (–328...+2,012°F)

  • Maximum pressure rating: 500 bar (7,252 psi)

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

Technical documentation

   

Technical data

 

 

   

Documents/Manuals/Software

 

 

   

Accessories/Spare parts

 

 

Source:Endress+Hauserpublic information from the website

市政污水处理

市政污水处理污水处理厂 · 热电阻应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热电阻应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热电阻应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热电阻应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电阻的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电阻,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;