Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

6AAB E+H热式质量流量计

 6AAB E+H热式质量流量计

热式质量流量计

The t-mass A 150 inline device is specially designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. its 4-wire technology is contained within a rugged compact aluminum housing. It is orderable either with display or as a blind version. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Compare

Gas

Measuring Principle Thermal
Product headline The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Sensor features Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement.
Inline version: DN 15 to 50 (½ to 2"). Process pressure up to PN 40, Class 300. A variety of process connections available.
Transmitter features Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.
Nominal diameter range DN 15 to 50 (½ to 2")
Wetted materials Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L)
Measured variables Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measurement error 3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
Measuring range 0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
Max. process pressure PN 40, Class 300
Medium temperature range –40 to +100 °C (–40 to +212 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push Buttons
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
Power supply DC 18 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates PED, CRN

The t-mass A 150 flowmeter is specifically designed for economical measurement and simple monitoring of common gases, particularly compressed air. It is the trend in submetering applications, with a robust one-piece aluminum housing and four-wire technology. Versions with and without a display are available. User-specific settings can be saved on the display and transferred from one device to another via the display.

 

Benefits

Suitable for measuring air, nitrogen, carbon dioxide and argon in small pipe diameters

Optimized process monitoring: convenient measurement even at low pressure and low flow rates

Economical measurement: easy installation, negligible pressure loss, maintenance-free

Reliable flow trend: multivariable measurement

Fast and effective commissioning: guided operating menu

High plant adaptability: self-diagnostics and error monitoring

Automatic data recovery for easy servicing

 

Application areas

The measuring principle offers a high operable measuring range and measures mass flow directly

Suitable for measuring air, nitrogen, carbon dioxide and argon in small-diameter pipes

Device features

 

Insertion version for nominal pipe diameters from DN 15 to 50 (1/2 to 2")

Process pressure up to PN 40, Class 300

Various process connection options

 

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

   

Measuring Principle Video

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 热式气体质量流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热式气体质量流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热式气体质量流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热式气体质量流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热式气体质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热式气体质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。