电磁流量计
The Promag 55S is designed for non-uniform, abrasive and corrosive fluids. The sensor uses an industry-optimized liner and is rugged, suitable for the most challenging environments and metering applications, such as wastewater treatment, pulp and paper, and primary raw materials and metallurgy. The Promag 55S is equipped with a high-performance transmitter that not only measures flow reliably but also calculates the solids content with low maintenance requirements.
Benefits:
Unique signal processing, outstanding signal stability
Highest safety factor - industry-optimized measuring electrodes and liner
-
Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss
-
Best performance - for demanding fluids, with built-in solids content detection
-
Highest safety level - integrated electrode cleaning
-
Automatic data recovery for easy maintenance
-
Maintenance-free - no moving parts
Application areas:
-
Bidirectional measuring principle not limited by pressure, density, temperature or viscosity
-
Ideal for measuring media with high solids content and high abrasiveness
Instrument features
-
Reinforced coil system
-
Wide range of optional liners
-
Solids content up to 80 % by weight
-
Four-line backlit display with touch control
-
Two switch outputs
-
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measuring principle video
Source: public information from the Endress+Hauser website
Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics. Superb signal stability due to unique signal processing. Ideal for the most demanding applications with high solids content and high abrasion. |
| Sensor features | Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Intensified coil system. Large range of liners. Solids content up to 80 % by weight. |
| Transmitter features | Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing. 4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus. |
| Nominal diameter range | DN 15...600 1/2"...24" |
| Wetted materials | Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum |
| Measured variables | Volume flow, electrical conductivity, mass flow |
| Max. measurement error | Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s) Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s) |
| Measuring range | 0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min) |
| Max. process pressure | PN 40, Cl. 300, JIS 20 K |
| Medium temperature range | 0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | Aluminum coated AlSi10Mg, carbon steel with protective varnish |
| Transmitter housing material | Powder-coated die-cast aluminum |
| Degree of protection | Standard: IP 67 (Type 4X enclosure) for transmitter and sensor Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor |
| Display/Operation | Liquid-crystal display: illuminated, four lines with 16 characters per line Onsite operation with three optical sensor keys |
| Outputs | 4...20mA (active/passive) Pulse-/ Frequency output (active/passive) Two status outputs |
| Inputs | Status Current input |
| Digital communication | HART, PROFIBUS DP/PA, FOUNDATION Fieldbus |
| Power supply | AC 20 to 260 V DC 20 to 64 V |
| Hazardous area approvals | ATEX, FM, CSA, UK Ex |
| Product safety | CE, C-tick, EAC marking |
| Pressure approvals and certificates | CRN, PED |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Drinking water approval:ACS, KTW-BWGL, NSF 61, WRAS BS 6920 |
Case Studies
市政污水处理污水处理厂 · 电磁流量计应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电磁流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电磁流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电磁流量计应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电磁流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电磁流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电磁流量计应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电磁流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电磁流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电磁流量计应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电磁流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电磁流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。