Field of application
Memosens CPS71E is specially designed for demanding processes. Its unique, contamination-resistant reference and its resistance to moisture ensure reliable measurement even in heavily polluted, aggressive media such as strong acids and bases. Thanks to Memosens 2.0 digital technology, CPS71E offers extended storage of calibration and process data providing the perfect basis for predictive maintenance. Pre-calibration in the lab and quick sensor exchange on site maximize process uptime.
Processes in chemical industry and monitoring of processes with:
High proportion of electrode poisons such as H2S
Quickly changing pH values
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Benefits
The electrode's unique ion trap prevents poisoning of the junction and reference, making it resistant to strong acids and bases and ensuring a long sensor lifetime.
The optional pressurized reference allows for reliable measurement in blocking media such as dispersions.
Flexible installation thanks to optional upside-down mounting
Inductive cable connection and non-contact signal transmission eliminate any problems due to moisture or corrosion and increase process integrity.
Fast sensor exchange on site reduces process downtime and operating costs.
Memosens 2.0 digital technology makes trend identification and predictive maintenance possible thanks to its extended storage of calibration and process data. The technology paves the way for advanced IIoT services.
pH:
| Measuring Principle | Potentiometric | |
| Application | Process technology and monitoring of processes with: • Rapidly changing pH values • High proportion of electrode poisons such as H2S |
|
| Characteristic | Digital pH electrode for chemical process with an ion trap for poison-resistant reference | |
| Measuring range | Application B: • pH: 0 to 14 Application H: • pH: 0 to 12 |
|
| Measuring principle | Gel compact electrode with ceramic junction and ion trap | |
| Design | All shaft lengths with temperature sensor Advanced gel technology |
|
| Material | Sensor shaft: Glass to suit process pH membrane glass: Type B, Type N Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
|
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.72, 8.86, 14.2 and 16.7 inch) |
|
| Process temperature | 1 to 140 °C (32 to 284 °F) | |
| Process pressure | 0,8 to 14 bar (11,6 to 203 psi) (absolute) | |
| Temperature sensor | NTC 30k | |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2. | |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology | |
| Ingress protection | IP68 | |
Technical Data
ComparepH
| Measuring Principle | Potentiometric |
| Application | Process technology and monitoring of processes with: • Rapidly changing pH values • High proportion of electrode poisons such as H2S |
| Characteristic | Digital pH electrode for chemical process with an ion trap for poison-resistant reference |
| Measuring range | Application B: • pH: 0 to 14 Application H: • pH: 0 to 12 |
| Measuring principle | Gel compact electrode with ceramic junction and ion trap |
| Design | All shaft lengths with temperature sensor Advanced gel technology |
| Material | Sensor shaft: Glass to suit process pH membrane glass: Type B, Type N Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.72, 8.86, 14.2 and 16.7 inch) |
| Process temperature | 1 to 140 °C (32 to 284 °F) |
| Process pressure | 0,8 to 14 bar (11,6 to 203 psi) (absolute) |
| Temperature sensor | NTC 30k |
| Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2. |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology |
| Ingress protection | IP68 |
Related Models
| Model | Name |
|---|---|
| CPS71E-AA7BTB2 | pH电极 |
| CPS71E-AA7BTC2 | pH电极 |
| CPS71E-AA7BTU2 | pH电极 |
| CPS71E-AA7HTP2 | pH电极 |
| CPS71E-NA7BTB2 | pH电极 |
| CPS71E-NA7BTU2 | pH电极 |
| CPS71E-NA7HTP2 | pH电极 |
Case Studies
市政污水处理污水处理厂 · PH应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · PH应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · PH应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · PH应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。