Nr Order Number Specifications
45 71228789 Terminal
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C.
Consists:
Connection terminal 3-Pol stamp 1,2
Connection terminal 2-Pol stamp A, B
Connection terminal 4-Pol stamp 20-23
Connection terminal 4-Pol stamp 24-26.
40 71228791 Integrated connection plate assembly
Usage:
Promag 400(C) with sensor D.
(C) = generation index C.
30 XPD0014- **Electronic Plug-in Promag 400 Index C
Complete main electronic module or
power supply, I /O-board and amplifier
as individual boards.
Complete main electronic module
contains:
Power supply, I /O-board, amplifier
board carrier, terminal connection
ribbon cable, installation marterial.
Individual boards contains:
Installation marterial
Power supply incl. terminal connection/
I /O-board incl. terminal connection/
Amplifier incl. ribbon cable.
D
AA
C6
GR
A
L
A
N
1
2
74
77
40 71228790 Split connection plate assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
44 50098018 sensor terminal board
Usage:
10/50/51/53/55/400/800
30 XPD0040- Electromagnetic 400 Index C Upgrade
Complete main electronic module or
power supply, I /O module with amplifier
as individual boards.
Complete main electronic module
contains:
Power supply, I /O module, amplifier
board carrier, terminals
ribbon cable, installation marterial.
Individual boards contains:
Installation marterial
Power supply incl. terminals/
I /O module incl. terminal connection and
amplifier incl. ribbon cable.
D
AA
C6
GR
A
L
A
H
I
L
M
N
1
2
66
67
68
70
71
39 71185788 T-DAT module
50 XPD0017- Display Module 4-wire,400 Index C
Usage:
Promag 400 Index C
Prosonic Flow 400 Index B.
1
2
20 71443262 cover
Usage:
Promag 400 (C)
(C) = generation index C.
Consists:
Version 1:
cover polycarbonate complete
2x hinge pin L= 58mm plastic.
Version 2:
cover polycarbonate complete
O-Ring 196,44x3,53 VMQ
wire with screw lock 1,5x150.
20 71384170 Promag400/500 cover
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass
500 digital, transmitter housing Alu.
Consists:
cover Alu complete included
O-Ring 196,40x3,53 HNBR
default and -50oC/-58oF
wire with screw lock 1,5x150.
24 50094038 wiring chamber cover
10/5X/40/8X/93/65/92F
24 71247838 **Service cover, detached
Usage:
10/5X/8X/8DF/8CN/92F/65/400/800
acc. service info SI01351D-1/06
Consists:
Cover Rep.kit for G14
O-Ring 110.00 x 4.50 HNBR, Grease
25 71278077 cover polycarbonate gasket
Usage:
Prosonic Flow 400
Promag/Promass/Prosonic Flow/t-mass
500 digital, Promag 400/800(C)
(C) = generation index C
transmitter housing polycarbonate.
Consists:
10x O-Ring 196,44x3,53 VMQ.
25 71278078 cover sealing ring
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass
500 digital, transmitter housing Alu.
Consists:
10x O-Ring 196,40x3,53 HNBR
default and -50oC/-58oF.
71 71228793 Housing Sealing Ring Assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
Consists:
Gasket EPDM for housing/sensor D/L/W.
O-Ring 29,87x1,78 HNBR for sensor-
plug L/W.
73 50098023 Housing Gasket Assembly
Usage:
10/50/51/53/55/400/800
Sensor: D/E/L/P/S/W
12 71228794 Housing Sealing Ring Assembly
Usage:
Promag 400(C) with sensor D/L/W.
(C) = generation index C.
Consists:
4x screw M5x18 hex cap DIN912 pla
4x spring washer M5 DIN7980 st.pla
for housing/sensor.
13 50098019 Kit parts housing FS Stnd/HT
Usage:
10/50/51/53/55/400/800
Sensor: D/E/H/L/P/S/W
15 71236702 cable plug
15 71236702 cable plug
17 50096840 cable plug
Kit 10 cable glands M20x1,5
15 71236703 Adapter
15 71236703 Adapter
17 50098041 Adapter
Kit 10 extension M20x1.5/G 1/2"
15 71236704 Adapter
15 71236704 Adapter
17 50098042 Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15 71236702 cable plug
15 71236702 cable plug
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236703 Adapter
15 71236703 Adapter
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236704 Adapter
15 71236704 Adapter
15 71236706 Connector Assembly
15 71236706 Connector Assembly
15 71236704 Adapter
15 71236704 Adapter
82 71228792 Display Protective Cover
Usage:
Prosonic Flow 400, Promag 400(C)
(C) = generation index C
Promag/Promass/Prosonic Flow/t-mass
500 digital, transmitter housing Alu.
Consists:
display protection 1.4301
installation material.
5X4CXX- Transmitter Conversion Assembly Promag 400
Same housing for compact/remote version.
Corrosion-resistant transmitter version.
With an integrated web server.
Important:
Transmitter only for remote design
(feature 015/A; feature 020/P/N).
Connection board incl. S-DAT of original
transmitter has to be reused in the new
transmitter only.
Conversion kit
(feature 015/ B /C/D/E/F/G/H/ I):
For conversion of an already existing
Promag to the new device generation or
to another device version.
Consists of all required
conversion parts.
AA
C6
GR
A
9
A
M
N
P
9
L
9
H
I
L
M
N
0
1
2
4
5
9
9
A
B
C
D
L
N
P
U
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AQ
AR
BA
E9
EA
EB
I7
P9
PA
PC
66
67
68
70
71
Z1
Z2
DK5005- Transmitter Mounting Component 400
Usage:
Promag 400/800
transmitter advanced.
B
DK5CA- Promag 10/50/51/53/55 Split Cable DK5CA
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
1
2
4
5
A
DK5DD- D-type electromagnetic flowmeter, seal
A set includes 2 flange seals
1H
25
40
50
65
80
A
9
C
L
T
DKD- MAGNETIC FLOW METER D, MOUNTING UNIT
The mounting set contains threaded
bolts, centering sleeves, nuts
washers and a pair of EPDM flange seals
orderable separately
as replacement for M1, M2
1H
25
40
50
65
80
9
C
L
T
1
2
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
CA
1