Nr Order Number Specifications
19 71115174 housing filter plug 316L, GT18, 1 group
Consists:
2x filter plug metall 316L.
1x pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
19 71115175 Housing Filter Plug (Brass/Nickel)
Consists:
2x filter plug brass nickel
pressure compensation filter.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
17 71115176 Housing Set Clips
Usage: housing GT18/GT19/GT20
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
20 71110281 aluminum cover
Material: 316L.
O-ring, EPDM, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
20 71110282 aluminum cover
Material: 316L.
O-ring NBR, PTFE coated.
Usage: FMP51/FMP52/FMP54/FMP55/
FMP56/FMP57, FMR51/FMR52/FMR53/
FMR54/FMR57, FMR62/FMR67, FHX50.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
20 71110292 aluminum cover
Material: plastics PBT-FR sight glas
PC.
O-ring EPDM, PTFE coated.
Usage: FHX50, FMP50/FMP51/FMP52/
FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/
FMR51/FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
20 71110293 aluminum cover
Material: plastics PBT, metallized.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
20 71110297 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
20 71110299 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
20 71383631 Shell
Material: 316L.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
20 71383666 Shell
Material: 316L.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
20 71383674 Shell
Material: Alu.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
20 71383675 Shell
Material: Alu.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71110284 aluminum cover
Material: 316L.
O-ring EPDM /PTFE coated.
Usage: terminal compartment Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110291 aluminum cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP51/FMP52/FMP54/FMP55/FMP56/FMP57,
FMR51/FMR52/FMR53/FMR54/FMR57,
FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Prowirl 200.
25 71110295 aluminum cover
Material: plastics PBT, metallized.
Usage: terminal compartment
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
25 71110301 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71110302 aluminum cover
Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
25 71185516 Cover
Material: 316L.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMP54/FMP56/FMP57, FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Prowirl 200.
25 71185517 aluminum cover
Material: aluminium.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/
FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
25 71185518 Cover
Material: plastic PBT, metallizied.
O-ring EPDM, PTFE coated.
Usage: terminal compartment
for overvoltage protection
not for Ex d/XP.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
25 71383668 Shell
Material: 316L.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71383670 Shell
Material: 316L.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71383671 Shell
Material: 316L.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71383679 Shell
Material: Alu.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71383680 Shell
Material: Alu.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
25 71383682 Shell
Material: Alu.
O-Ring FVMQ.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
65 71110303 Enclosure Seal Kit
Consists:
O-ring 88.5x3.53 EPDM/PTFE
cover electronics compartment
housing GT19.
O-Ring 88.5x3.53 NBR
cover electronics compartment
housing GT18, GT20.
O-ring 91.67x3.53 EPDM/PTFE
cover terminal compartment
housing GT19.
O-Ring 91.67x3.53 NBR
cover terminal compartment
housing GT18, GT20.
O-ring 50.39x3.53 EPDM/PTFE
housing/sensor.
FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
65 71384797 sealing device
Consists:
O-Ring 88,5x3,53 FVMQ
cover electronics compartment
housung GT18, GT20.
O-Ring 91,67x3,53 FVMQ
cover terminal compartment
housung GT18, GT20.
Usage: FMP51/FMP54, FMR51/FMR52/FMR54.
Usage: Prowirl 200.
71450381 M12 connector, IP66/68 NEMA4X/6P,Pro TOF
For electrical connection.
Usage:
FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/
FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/
FMR54/FMR57, FMR60/FMR62/FMR67.
34 71108594 I/O Modules
Non-Ex, Ex.
1x current output HART.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
34 71108595 I/O Modules
Non-Ex, Ex.
1x current output HART.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108595 I/O Modules
Non-Ex, Ex.
1x current output HART.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108595 I/O Modules
Non-Ex, Ex.
1x current output HART.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108595 I/O Modules
Non-Ex, Ex.
1x current output HART.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108599 I/O Modules
Non-Ex, Ex.
1x current output HART, 1x PFS.
PFS=switch output.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57. FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
34 71108603 I/O Modules
Non-Ex, Ex.
PROFIBUS PA.
PFS=switch output.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108603 I/O Modules
Non-Ex, Ex.
PROFIBUS PA.
PFS=switch output.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71108603 I/O Modules
Non-Ex, Ex.
PROFIBUS PA.
PFS=switch output.
Version 1.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
34 71164940 I/O Modules
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200
Promag 200.
34 71164940 I/O Modules
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200
Promag 200.
34 71164940 I/O Modules
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200
Promag 200.
34 71164940 I/O Modules
Non-Ex, Ex.
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass 200, Prowirl 200
Promag 200.
34 71187812 I/O Modules
Version 2.
Not for Ex d/XP.
LP=low powered.
1x current output HART.
Usage: FMP50/FMP51/FMP52/FMP53/FMP54/
FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/
FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
34 71207473 I/O Modules
Non-Ex, Ex.
10.4-48VDC.
1x current output HART.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
34 71207474 I/O Modules
Non-Ex, Ex.
Current output, 4-20mA HART 4-20mA
analog.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
34 71207475 I/O Modules
Non-Ex, Ex.
90-253VAC.
1x current output HART.
Version 2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
37 71110279 Terminal Kit 4-Wiring, I/O Modules
Consists:
2x terminal 2-pole, green.
2x terminal 2-pole, red.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
37 71110280 Terminal Kit 2-Wiring, I/O Modules
Consists:
4x terminal 2-pole, green.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200
Prowirl 200.
71248380 Spare Parts
Consists:
transmitter board, ribbon cable
cable gland, M12 bushing, VA .,
Adaption to NPT1/2.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
Usage: Prowirl 200, Promass 200
Promag 200, Prosonic Flow 200.
71206552 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71206554 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71206555 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71206556 cable
Connection cable, shielded.
Usage: FHX50, FHX50B.
71197334 transmitter FHX50
Consists:
electronics, ribbon cable.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57.
Usage: Promass200, Prowirl 200
Promag 200, Prosonic Flow 200.
71296840 Plug M12, VA
To connect FHX50.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Not for dust Ex.
Usage: Prowirl 200, Promass 200
Promag 200, Prosonic Flow 200.
71128617 Overvoltage protector
4-20mA HART.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
71128619 Overvoltage protector
4-20mA HART, PROFIBUS PA, FOUNDATION
Fieldbus, Imp./Freq./Switch output.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/
FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200, Prosonic Flow 200
Promag 200, Prowirl 200.
30 XPF0001- guided wave radar Levelflex FMP5x electronic plug-in
Main electronics.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57.
X
1
2
3
4
9
M
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AO
AP
AQ
AR
L8
L9
LA
LC
LE
LF
LG
LH
LI
71
72
73
74
75
76
77
78
Z1
40 XPD0024- Display Module
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
t-mass 150, Promag 200, Prowirl 200.
Consists:
Display SD02, helix cable
ribbon cable, connector cover.
A
C
00
40 XPD0025- Display Module
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57,
FMR60/62/67, FHX50.
Promass 200/TB2, Prosonic Flow 200
Promag 200, Prowirl 200.
Consists:
Display SD03 illuminated, ribbon cable
connector cover.
A
E
00
57 71114459 O-ring
Usage: FMP50/FMP51 G3/4, NPT3/4.
57 71114460 O-ring
Usage: FMP51 G3/4, NPT3/4.
57 71114461 O-ring
Usage: FMP51 G3/4, NPT3/4.
57 71114462 O-ring
Usage: FMP51.
57 71114463 O-ring
Usage: FMP51.
57 71114464 O-ring
Usage: FMP51.
57 71294076 O-ring
Usage: FMP51.
56 71114452 counterweight
Material: 316L.
Grub screw M6x10, hexagon screw.
Usage: FMP50/FMP51/FMP54/FMP56/FMP57.
71373490 PEEK rope
Rope spacer for rope 4mm.
D=48-95 mm/1.88-3.74 in.
Diameter adaptable.
Tmax 250oC/482oF.
Material: PEEK.
FDA, EG 1935/2004, EU 10/2011 compliant.
Usage: rope assembly FMP50/FMP51/
FMP52/FMP54/FMP55.
71373492 PEEK rope
Rope spacer for rope 4mm.
D=48-95 mm/1.88-3.74 in.
Diameter adaptable.
Tmax 250oC/482oF.
Material: PEEK.
FDA, EG 1935/2004, EU 10/2011 compliant.
Usage: rope assembly FMP50/FMP51/
FMP52/FMP54/FMP55.
71381909 PEEK rod
Spacers for rods 12mm/0.5in.
D=48-95 mm/1.89-3.74in.
Diameter adaptable.
Tmax 250oC/482oF.
Material: PEEK.
FDA, EG1935/2004, EU10/2011 compliant.
Usage: Rod mounting FMP51/FMP54.
71536664 cable antenna centering plate d = 75mm/2,95 ", 316L
For pipe diameter DN80/3" DN100/4 ".
Material: 316L.
Grub screw M6x10.
Usage:FMP51, FMP54.
71536668 centering counterweight d = 45mm,h = 60mm,316L
For pipe diameter DN50/2 ".
Material: 316L.
Grub screw M6x10.
Usage:FMP51, FMP54.
71536671 Clique counterweight d = 75mm,h = 30mm,316L
For pipe diameter DN80/3 ".
Material: 316L.
Grub screw M6x10.
Usage:FMP51, FMP54.
71536672 Cancing counterweight d = 95mm,h = 30mm,316L
For pipe diameter DN100/4 ".
Material: 316L.
Grub screw M6x10.
Usage:FMP51, FMP54.
71377355 Bluetooth module
Module for wireless data communication.
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/
FMR52/FMR53/FMR54/FMR56/FMR57,
FMR60/FMR62/FMR67.
55 XPF0005- FMP51 probe no process connection
Usage: existing process connection
FMP51.
8A
99
AA
B2
B3
B4
BA
BB
BC
BD
BG
BH
BL
C2
C3
CA
CB
FA
FB
FD
G2
G3
G4
GA
GB
GC
GD
GG
GH
GL
GR
I2
I3
I4
IA
IB
IC
ID
IG
IH
IL
JC
K2
K3
K4
KA
KB
KC
KD
KG
KH
KL
KR
MA
MC
MH
N2
N3
NA
NB
NC
NG
NH
TA
TC
TF
TH
U2
U3
U4
UA
UB
UC
UD
UG
UH
UL
UR
AA
AB
AC
AD
AL
AM
BA
BB
BC
BD
LA
LB
LC
LD
LE
LF
LG
LH
MB
MD
ME
MF
MG
MH
YY
A4
B3
C3
E1
Y9
AEJ
AEM
AFJ
AFM
AGJ
AGM
AHJ
AJJ
AKJ
AOJ
AQJ
AQM
ARJ
ARM
ASJ
ASM
ATJ
ATM
AUJ
CFJ
CFM
CGJ
CGM
CHJ
CHM
CJJ
CKJ
CQJ
CQM
CRJ
CRM
CSJ
CSM
CTJ
CTM
ESJ
GDJ
GGJ
KEJ
KFJ
KGJ
KHJ
RDJ
RGJ
WFJ
WQJ
WRJ
WSJ
YYY
I7
I9
JA
JB
JE
JF
K9
KG
KI
L8
L9
LE
LF
LG
LH
LI
M9
O9
OA
OB
OC
OD
OE
OK
OL
OM
SA
Z1
70 71114823 HF coaxial cable
Usage: FMP50/FMP51/FMP52/FMP54/
FMP55/FMP56/FMP57, sensor remote.
70 71235564 HF coaxial cable
Up to 100oC.
Usage: FMP50/FMP51/FMP52/FMP54/
FMP55/FMP56/FMP57, sensor remote.
70 71235578 HF coaxial cable
Up to 100oC.
Usage: FMP50/51/52/54/55/56/57
sensor remote.
71102216 Installation Components
Material: 316L.
Usage: wall/pipe mounting (2").
FMB50, FMB51, FMB52, FMB53, FMB70,
FMP50, FMP51, FMP52, FMP53, FMP54,
FMP55, FMP56, FMP57, PMC51, PMC71,
PMP51, PMP55, PMP71, PMP75, PMP51B,
PMC51B, PMP71B, PMC71B.
71162242 Cover | GT18/GT19/GT 20,316L
Usage: FMP50/FMP51/FMP52/FMP53/
FMP54/FMP55/FMP56/FMP57,
FMR50/FMR51/FMR52/FMR53/FMR54/
FMR56/FMR57, FMR60/FMR62/FMR67.
Usage: Promass 200/TB2
Prosonic Flow 200, Promag 200, Prowirl
200.
71069064 center washer PEEK 48-95mm
Spacers for rods 16mm/0.63in.
D=48-95 mm/1.89-3.74in.
Diameter adaptable.
Tmax 250oC/482oF.
Material: PEEK.
FDA, EG1935/2004, EU10/2011 compliant.
Usage: Rod mounting FMP51/FMP54.
71069065 center washer PFA 37mm/1.46in
Spacers for rods 16mm/0.63in.
Tmax 250oC/482oF.
Material: PFA.
FDA, EG1935/2004, EU10/2011 compliant.
Usage: FMP51/FMP52/FMP54/FMP55.
71157270 center washer PFA 37mm/12mm
Spacers for rods 12mm/0.5in.
Tmax 250oC/482oF.
Material: PFA.
FDA, EG1935/2004, EU10/2011 compliant.
Usage: FMP51.
71162453 center washer PFA 37mm/8mm
Spacers for rods 8mm/0.33in.
Tmax 250oC/482oF.
Material: PFA.
FDA, EG1935/2004, EU10/2011 compliant.
Usage: FMP51.
54 71156686 screw M10 * 1, material Alloy C22
Usage: divisible rod, FMP51/FMP54.
59 71023427 Washer
Levelflex M, 6mm rope/16mm rod
52014249 4mm cable insulated fixing accessories
Isolator: PPS.
Ring bolt: stainless steel.
Usage: FMP40, FMP56.
57 71185027 sealing ring
Process gasket DIN7603-A.
Usage: process connection
FMI51/FMI52, FTI51/FTI52,
FMP50/FMP51/FMP56, FMR62, QMW43,
FTL31/FTL33, FTW23/FTW33,
FTL50/FTL50H/FTL51, FTL80/FTL81.
57 52014047 sealing ring
Process gasket
process connections G1-1/2
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
CA
FA
IA
KA
MA
NA
UA
UR
1