Nr Order No. Specifications
71044062 Device Pack
2x screws, 1x sealing CDI-connector
71386275
TMT142X-DA Spare parts TMT142X
Spare parts TMT142X
TMT142X-DB Spare parts TMT142X
Spare parts TMT142X
F TMT142X-HI Spare parts TMT142X
Spare parts TMT142X
F TMT142X-HL Spare parts TMT142X
Spare parts TMT142X
TMT162A-MA TMT162A Accessories
TMT162A-MB TMT162A Accessories
TMT162A-MD TMT162A Accessories
TMT162X-DA Spare parts TMT162X
TMT162X-DB Spare parts TMT162X
TMT162X-DC Spare parts TMT162X
F TMT162X-HI Spare parts TMT162X
F TMT162X-HL Spare parts TMT162X
51006845 cable plug
Cable gland NPT 1/2, D4-8.5, IP68
51007995 Mounting Bracket
Mounting bracket SS316L, tube 1,5-3"
A TU121- TC Insert TU121, General Purp, US Style
Spare part.
Thermocouple Insert spring loaded.
Thermocouple comply with EMF tables
ASTM E-230 and IEC60584.
Color codes per ASTM E-230.
F TU401- Enclosure TU401, US Style
XPT0004- Spare Parts Kit Cover TA30R
cover of connecting head
F TA30H- Terminal Head TA30H
Retainer for terminal block or head
transmitter optional display.
Design: explosion proof.
Cover: screwed, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50#150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
Protection Ex d/XP: IP66/67 (housing).
A TA30R- Terminal Head TA30R
Retainer for terminal block
or head transmitter optional display.
Cover: screwed, optional window.
Material: Stainless Steel 316L.
Colour: Steel (no coating).
Ambient Temp.: -50...85/130 oC
(display/standard).
Protection: IP66/68, NEMA4X;
IP69K (housing).
:: easy wiring through best
accessibility.
:: compact desing and low weight.
E TU54- Thermowell TU54, Flanged US Style
Bar stock Thermowell, CRN Number.
The Flange is welded on.
TMT142E- Electronic TMT142E
TMT162E- Electronic TMT162
TMT181- **iTEMP TMT181, Head Transmitter PCP
Product being phased out
limited availability.
Temperature transmitter,PC-programmable.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanic isolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
TMT182- **iTEMP TMT182, Head Transmitter HART
Product being phased out
limited availability.
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanicisolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
TMT82- iTEMP TMT82, Transmitter HART
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
TMT84- iTEMP TMT84, Transmitter PA
Dual sensor input.
Advanced diagnostics:sensor monitoring.
PROFIBUS PA Profile 3.02.
Galvanic isolation 2kV.
Application: RTD, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN EN50446.
Factory setup:
CH1: Pt100, 3-wire, oC.
CH2: inactive.
Differing configuration optional
selectable.
TMT85- iTEMP TMT85, Transmitter FF
Dual sensor input.
Advanced diagnostics: sensor monitoring.
FOUNDATION Fieldbus protocol
Galvanic isolation 2 kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN EN50446.
Factory setup:
CH1: Pt100, 3-wire, oC.
CH2: inactive.
Differing configuration optional
selectable.
F TMT142G- Housing TMT142G
F TMT162G- Housing TMT162
TXU10- Configuration Kit TXU10
for PC-programmable devices.
set-up programme interface cable for PC
with USB-Port.
READWIN- Readwin 2000 Operation Read. software
TID10- Display Unit Head Transmitter
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84, TMT82, TMT71
TMT72.
FXA195- Commubox FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
TH55- TC Assembly TH55, Spring US Style
Spring loaded temperature measuring
device, without thermowell.
Comply with EMF tables of ASTM E-230
and IEC60584.
Color Codes per ASTM E-230.