Nr Order No. Specifications
71044061 Device Pack
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector
52028179 Washer
Profile gasket for cover
Stainless steel housing F15
60011599 Washer
D=6.1mm, AISI316, set includes 10
gaskets.
60011600 Washer
D=6.1mm, PTFE, set includes 10 gaskets
60017971 Display
Display LC for TA20J
71043745 Atmospheric compensation filter port
Consists:
filter plug plastic
Pressure compensation filter, O-ring.
Usage: housing F15.
Non Ex.
71313382 Connector
71586353 Spare parts kit gasket ring D21/d6 Viton
Packung unit: 3 pieces
71586366 Spare parts kit gasket ring D21/d6 Neop.
Packung unit: 3 pieces
71586370 Spare parts kit gasket ring D21/d3 Viton
Packung unit: 3 pieces
71586372 Spare parts kit gasket ring D21/d3 Neop.
Packung unit: 3 pieces
71367427 Gasket
Packing unit: 10 pieces
C 71111513 ceramic terminal
C 71111514 ceramic terminal
C 71111515 ceramic terminal
71586415 Spare parts kit O-ring TA20R
44.17x1.78 EPDM labs free, black
Packing unit: 5 pieces
A TPR100- thermal resistance core TPR100
Mineral insulated cable (MgO)
Replaceable insert acc.EN60751.
max. measuring range: -200...600 oC
(depending on configuration)
3
A
B
G
H
J
P
AA
AC
AE
AF
AH
AL
AM
AP
XX
YY
1
2
3
C
F
3
7
A
B
C
D
F
G
H
P
Y
0
1
2
0
A
C
E
G
K
M
Y
0
9
F TA50- Mounting Mount Sleeve Fitting TA50
Screw in.
CB
CP
HB
HP
B TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
A1
B1
B2
D1
E1
A
1
2
A
A2
B1
B3
C1
F1
B TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
A1
B1
B2
D1
D2
D3
E1
A
1
2
A
A2
B1
B3
C1
F1
B TID10- temperature transmitter display TID10
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84.
A1
B1
B2
D1
E1
D TA20A- **Junction box TA20A
Product being phased out
limited availability.
Connection head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material: Aluminium epoxy resin coating
Area temperature : max. 100 oC;
ATEX: 95 oC.
A
2
5
6
7
A
1
D TA20B- junction box TA20B
Connecting head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material:Polyamid black
Ambient temperature: max. 80 oC
Protection: IP65
A
2
C
1
D TA21E- Junction Box TA21E
Retainer for terminal block or head
transmitter.
Cover: srewable.
Material: Aluminum.
Max. temp.: 100 oC; ATEX 95 oC.
Protection: IP65.
A
1
A
B
C
B
A
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
1
AA
TXU10- Instrument debugging package TXU10
for PC-programmable devices
The program sets the connection line for a PC with USB interface
AA
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
G
1
D TA30A- lug TA30A
Retainer for terminal block or head
transmitter optional display.
Cover: low, hinged, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
A
B
C
1
2
B1
B3
D TA30D- Terminal lug TA30D
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
1
A
B
C
B1
B3
D TA30P- junction box TA30P
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: Polyamid PA12 antistatic.
Colour: black.
Ambient temp.: -40...120oC (housing).
Protection: IP65 (housing).
1
A
B TMT180- module temperature transmitter TMT180
Temperature transmitter,PC-programable.
Application: RTD.
2-wire 4-20mA.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
A
1
2
1
2
2
3
4
XX
A
B
B TMT181- **Module temperature transmitter TMT181
Product being phased out
limited availability.
Temperature transmitter,PC-programmable.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanic isolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
1
2
A
B
G
H
2
3
4
1
B
A
B
B TMT182- **Module temperature transmitter TMT182
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, SIL2, galvanic isolation
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN43729.
UL listed.
GL (German Llyod) Marine.
1
2
A
B
G
H
K
D
E
F
1
B
A
B
B TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.
AA
B2
BA
IA
NA
NN
A
1
2
A
B1
B3
C1
A1
A1
AA
A1
A2
F1
LA