Nr Order Number Specifications
B 50103475 PW 72 explosion-proof signal processing module
Kit meas. amplifier PW 72 Ex
A 50103476 Insourced current output module
Kit I /O-board PW 72/73 HART Exi
A 50103477 current/pulse output module
Kit I /O-board PW 72/73 HART/pulse Exi
A 50103478 **Inen safe PA output module
Kit I /O-board PW72/73 PROFIBUS PA Exi
A 50107084 **Inen safe FF module
Kit I /O-board PW72/73Found.Fieldbus Exi
E 50106382 flameproof current output module
Kit I /O-board PW 72/73 HART Exd
E 50106384 flameproof current/pulse output module
Kit I /O-board PW 72/73 HART/pulse Exd
A 50106383 **Flameproof PA Module
Kit I /O-board PW 72/73 PROFIBUS PA Exd
A 50107085 **Flameproof FF Module
Kit I /O-board PW72/73Found.Fieldbus Exd
E 50106385 Flameproof PA/FF Junction Module
Kit conn. board PW72/73PROFIB.PA/FF Exd
C 50103472 72/73/92F with key display module (HART)
Kit display 72/73/92F w. keyboard(HART)
C 71123423 72/73 with key display module (HART)
Language:EN DE FR ES IT NL NO SV
FI PT PL CS ZH JA RU
D 50103473 72/73/92F Keyless Display Module (PA/FF)
Kit display72/73/92F w/o keyboard(FF/PA)
D 71123425 72/73 Keyless Display Module (FF/PA)
Language: EN DE FR ES IT NL NO SV
FI PT PL CS ZH JA RU
G 50103474 PW 72/73 Pre-Amplification Module
Kit preamplifier PW 72/73
F 50103884 Transmitter wiring cavity wiring board
H 50103885 sensor terminal board
25 50108141 72/73/92F wiring block
Kit Terminal Block 72/73/92F
8 50103526 72/73/92F Glass Cover
Kit cover 72/73/92F with window
9 50103527 72/73/92F Blind Cover
Kit cover 72/73/92F blind version
12 50103527 72/73/92F Blind Cover
Kit cover 72/73/92F blind version
10 50106386 72/73/92F Flameproof Wiring Cavity Cover
72/73/92F/8FF/8FE
20 50103883 Cover
1 50103658 cable gland
1 50103658 cable gland
1 50103658 cable gland
1 50098036 10 M20x1.5 explosion-proof cable plugs
Kit 10 cable glands M20x1.5 Ex
1 50098036 10 M20x1.5 explosion-proof cable plugs
Kit 10 cable glands M20x1.5 Ex
1 50098036 10 M20x1.5 explosion-proof cable plugs
Kit 10 cable glands M20x1.5 Ex
1 71120601 Cable Gland Assembly
1 71120602 Cable Gland Assembly
1 50098042 M20x1.5/NPT 1/2 "Adapter
Kit 10 extension M20x1.5/NPT 1/2"
1 50098042 M20x1.5/NPT 1/2 "Adapter
Kit 10 extension M20x1.5/NPT 1/2"
1 50098042 M20x1.5/NPT 1/2 "Adapter
Kit 10 extension M20x1.5/NPT 1/2"
1 50098041 M20x1.5/G 1/2 "adapter
Kit 10 extension M20x1.5/G 1/2"
1 50098041 M20x1.5/G 1/2 "adapter
Kit 10 extension M20x1.5/G 1/2"
1 50098037 PA master cable plug
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
1 50098037 PA master cable plug
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
1 50094984 FF master cable plug
Kit Cable gland Found. Fieldbus
1 50094984 FF master cable plug
Kit Cable gland Found. Fieldbus
3 50097147 Ground strap/lid locking buckle
10/1YH/23/65/72/73/91W/92F/8FF/8FE/8CM
4 50103528 circuit board fixing plate
it Circuit board 72/73/92F field hous.
5 50103529 Display Panel Mounting Bracket
6 50103892 Washer
7 50103893 Washer
22 50103484 Separate 10 m cable
Kit cable PW72/73 remote version 10m
22 50103485 separated 10 m explosion-proof cable
Kit cable PW72/73 remote version 10m Ex
22 50103486 Separate 30 m cable
Kit cable PW72/73 remote version 30m
22 50103487 Separate 30 m explosion-proof cable
Kit cable PW72/73 remote version 30m Ex
22 71109659 Cable Assembly
22 71109660 Cable Assembly
22 71109661 Cable Assembly
22 71109663 Cable Assembly
72XXX- **Prowirl 72W/F Transmitter 72XXX
vortex flowmeter
Sensor:
XXX 72F, 72W
Version:
XX Transmitter only
Additional Test:
1 Basic version
9 Special version, TSP-no. to be spec.
Approval:
1 ATEX II1G IECEx Z0 Ex ia IIC Z= Zone
2 ATEX II1/2G IECEx Z0/1 Ex ia IIC Z= Zone
3 ATEX II1/2G IECEx Z0/1 Ex d(ia) IIC Z= Zone
9 Special version, TSP-no. to be spec.
A Non-hazardous area
C ATEX II2G IECEx Z1 Ex d(ia) IIC Z= Zone
D ATEX II2G IECEx Z1 Ex ia IIC Z= Zone
F ATEX II1/2GD IECEx Z0/1,21 Ex d(ia) IIC DIP A21 Z=Zone
G ATEX II1/2GD IECEx Z0/1,21 Ex ia IIC DIP A21 Z=Zone
H ATEX II 3G EEx nA
N FM IS Cl, I ,II,III Div. 1,2/CSA Cl. I ,II,III Div. 1,2; Cl. I zone 0
P FM XP Cl. I Div. 1 / CSA Cl. I Div. 1, A- G; Cl.II;Cl.III, FACTORY SEALED
U TIIS Ex d (ia) IIC T4
W TIIS Ex d (ia) IIC T1
Version:
9 Special version, TSP-no. to be spec.
A Compact, Alu, IP67/ NEMA4X
E Remote, cable 10m/30ft, IP67 NEMA4X
F Remote, cable 30m/90ft, IP67 NEMA4X
M Remote, cable armoured 10m/30ft, IP67 NEMA4X
N Remote, cable armoured 15m/50ft, IP67 NEMA4X
O Remote, cable armoured 20m/70ft, IP67 NEMA4X
P Remote, cable armoured 30m/90ft, IP67 NEMA4X
Cable Entry:
9 Special version, TSP-no. to be spec.
A Gland M20 (EEx d> thread M20)
B Thread NPT 1/2
C Thread G 1/2
D Gland M20 x 1.5
F Gland G 1/2", Ex d Shimada
J Bus connector
K Bus connector gland M20
L Bus connector thread NPT 1/2
Display; Operating:
0 W/o display; remote configuration
4 2-line; push button, Hart
6 2-line display; PA, FF, remote configuration
9 Special version, TSP-no. to be spec.
C 2-line EA; push button, HART; EA=12 languages ZH RU JA
D 2-line graphic EA; PA, FF, EA=12 languages ZH RU JA remote configuration
T TLV Label Version w/o display; remote configuration HART
Adjustment; Software Feature:
9 Special version, TSP-no. to be spec.
A Factory setup; basic version
Output, Input:
9 Special version, TSP-no. to be spec.
A 4-20mA SIL HART Impulse, PFM
H ***PROFIBUS PA
K ***FOUNDATION Fieldbus
W 4-20mA SIL HART