Nr Order No. Specifications
F 50096745 Power Board 50/51/53 85-260VAC
Kit power s. B. PMAG5X 85-260VAC
F 71039466 power board
HE = harsh environment
F 71039466 power board
HE = harsh environment
F 50096747 Power Board Electromagnetic 50/51/53 20-55VAC 16-62VDC
F 71039468 power board
HE = harsh environment
7 50094002 10 800mA fuses
Kit 10 fuses 250 VAC T800 MA
7 50094003 10 2A fuses
Kit Bus/connec. B .5X/40/8X/65 field hous.
B 50106085 Amplifier Board
Language: FR, ES, IT, NL, PT, DE, EN
B 71039454 Amplifier Board
Language: FR, ES, IT, NL, PT, DE, EN
HE = harsh environment
B 50106087 Amplifier Board
Language: JA, ID, EN
B 71039456 Amplifier Board
Language: JA, ID, EN
HE = harsh environment
B 50106086 Amplifier Board
Language: SV, FI, NO, RU, PL, CS, EN
B 71039455 Amplifier Board
Language: SV, FI, NO, RU, PL, CS, EN
HE = harsh environment
B 50108133 Pmag 53 Chinese signal processing module
CN= language ZH EN
B 71039457 Amplifier Board
Language: ZH, EN
HE = harsh environment
B 71261680 Amplifier Panel Assembly
Language: DE FR IT ES EN
B 71261682 Amplifier Panel Assembly
Language: DE FR IT ES EN
HE = harsh environment
B 71261686 Amplifier Panel Assembly
Language: RU NL PT CS EN
B 71261687 Amplifier Panel Assembly
Language: RU NL PT CS EN
HE = harsh environment
B 71261690 Amplifier Panel Assembly
Language: ZH PL ID EN
B 71261692 Amplifier Panel Assembly
Language: ZH PL ID EN
HE = harsh environment
B 71261693 Amplifier Panel Assembly
Language: JA SV NO FI EN
B 71261694 Amplifier Panel Assembly
Language: JA SV NO FI EN
HE = harsh environment
C 50098300 53/83/93/65 Explosion-proof Output Module
Kit com 53/83/93/65 curr/freq/2Relay Ex
C 71039475 input/output board
53/55/83
HE = harsh environment
C 50098301 53/83/93/65 Explosion-proof Output Module
Kit com 53/83/93/65 curr/freq. out Ex
C 71039476 input/output board
53/55/83
HE = harsh environment
C 71066579 input/output board PA Ex
50/53/55/80/83/93/65
C 71066580 input/output board
HE = harsh environment
C 71095035 input/output board C14 EX
53/55/83/93/65
C 71095037 Explosion-proof input/output board HE C14
53/55/83
HE = Harsh Environment
C 71021742 Communication Module
C 71039484 input/output board
HE = harsh environment
D 71021743 ModbusRS485 stat.In 2Interf.Ex communication components
53/83/84/65/8CN/8DF
D 71039485 input/output board
53/83/84/8CN/8DF
HE = Harsh environment
D 50108002 Communication Module
53/55/83/93
D 71039486 input/output board
53/55/83
HE = harsh environment
D 50096833 53/8X/93/65 Explosion-proof Output Module
Kit Com53/8X/93/65 curr.out 3 Interf.Ex
D 71039477 input/output board
53/55/8X
HE = harsh environment
D 71105712 53/83 input and output analog Ethernet
Including Subprint Ethernet
2 50096834 53/8X/93/65 current output sub-module
Kit Sub PCB 53/8X/93/65 current out
2 71039487 sub-output board current output
53/55/8X
HE = harsh environment
3 50096835 53/8X/93/65 Frequency Output Submodule
Kit Sub PCB 53/8X/93/65 frequency out
3 50096835 53/8X/93/65 Frequency Output Submodule
Kit Sub PCB 53/8X/93/65 frequency out
3 71039489 sub-output board frequency output
53/55/80/83
HE = harsh environment
3 71039489 sub-output board frequency output
53/55/80/83
HE = harsh environment
4 50096837 53/8X/93/65 Status Input Submodule
Kit Sub PCB 53/8X/93/65 Status input
4 71039492 Sub Output Board Status Output
53/55/8X
HE = harsh environment
5 50096836 Pline53/83/93 relay output sub-module
Kit Sub PCB Pline53/83/93 Relay out
5 50096836 Pline53/83/93 relay output sub-module
Kit Sub PCB Pline53/83/93 Relay out
5 71039491 Sub Output Board Relay Output
53/55/83/84/8CN/8DF
HE = Harsh environment
5 71039491 Sub Output Board Relay Output
53/55/83/84/8CN/8DF
HE = Harsh environment
6 50098562 53/53/65 current input sub-module
53/55/83/65
6 71039488 sub-output board current input
53/55/83
HE = harsh environment
37 71105711 53/83 PCB Ethernet
J 50096755 53/83/84/93 Wall Mounted Display Module
Kit display mod 53/83/84/93 Wall encl
E 50096754 Proline 53/83/84/93 Display Module
Kit display mod Pline 53/83/84/93
21 50094017 5X/8X/9X/65 Wall Mount Bus Interface
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
G 50094016 5X/40/8X/65 Field Mount Bus Interface
G 71105709 53/83 Ethernet Bus Interface Board
19 50094015 Wall-mounted wiring module
19 71039496 Wall-mounted wiring board
HE = harsh environment
18 50094014 Wall-mounted wiring module
Kit connec. board In/Output Wall encl
A 50098018 Sensor Part Terminal
Usage:
10/50/51/53/55/400/800
A 71039497 Sensor Part Terminal
Usage:
10/50/53/55
HE = harsh environment
29 50108139 5X/8X/40/65 Field Mounted Terminal Blocks
Kit Termin.Block field hous. 5X/8X/40/65
30 50108140 5X/8X/9X/65 Wall Mounted Terminal Blocks
Kit Termin.Block Wall encl. 5X/8X/9X/65
1 50094004 Transmitter Data Module
Kit T-DAT Transmitter Data Chip
S 71003948 with setting S-Data module
Serialnumber is forceful required
8 50094026 5X/40/8X/65 glass cover
Kit Cover 5X/40/8X/65 with window
9 50094028 5X/40/8X/65 Blind Cover
Kit Cover 5X/40/8X/65 version blind
10 50094038 wiring chamber cover
10/5X/40/8X/93/65/92F
26 50094038 wiring chamber cover
10/5X/40/8X/93/65/92F
15 50098036 10 M20x1.5 explosion-proof cable plugs
Kit 10 cable glands M20x1.5 Ex
15 50096840 10 M20x1,5 cable plugs
Kit 10 cable glands M20x1,5
15 50098042 M20x1.5/NPT 1/2 "Adapter
Kit 10 extension M20x1.5/NPT 1/2"
15 50098041 M20x1.5/G 1/2 "adapter
Kit 10 extension M20x1.5/G 1/2"
15 50098037 PA master cable plug
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
15 50094984 FF master cable plug
Kit Cable gland Found. Fieldbus
15 71029351 cable plug
15 71029352 cable plug
15 71105713 53/83 Ethernet bus interface
15 71105713 53/83 Ethernet bus interface
12 50096839 circuit board bracket (field/stainless steel housing)
Kit Circuit board cpl field/SS-housing
14 50099102 cast aluminum/stainless steel housing sleeve
13 50096841 Ground strap/lid locking buckle
Kit Ground terminal / Cover clamp
20 50094041 Wall-mounted sealing cover
Kit Seal cover to Wall enclosure
11 50094050 Field-mounted sealing cover
Kit 10 Seal cover to field housing
22 50098020 Mounting screws and mounting accessories
Usage:
10/23/50/51/53/55
Sensor: D/E/H/L/P/S/W
24 50098019 Mounting screws and mounting accessories
Usage:
10/50/51/53/55/400/800
Sensor: D/E/H/L/P/S/W
25 50098023 Washer
Usage:
10/50/51/53/55/400/800
Sensor: D/E/L/P/S/W
23 50098024 Washer
Usage:
10/23/50/51/53/55
Sensor: D/E/L/P/S/W
DK5CA- Promag 10/50/51/53/55 Split Cable DK5CA
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
Cable, Remote Version:
1 5m/15ft
2 10m/30ft
4 ..... m
5 ..... ft
Approval:
A Non-hazardous area ATEX II 3G, FM/CSA
53XXX- **Promag 53 Transmitter 53XXX
electromagnetic flowmeter
Application:
XXX Promag 53W, 53P, 53H, 53L, 53E
Version:
XX Transmitter only
Approval:
A Non-hazardous area
J ATEX II 3G Ex nA nC IIC
R FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
Housing:
1 Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
3 Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
9 Special version, TSP-no. to be spec.
A Compact Alu, IP67 NEMA4X
C Wall Alu, IP67 NEMA4X
P Compact Alu, IP67 NEMA4X, HE HE= harsh environment
S Wall Alu, IP67 NEMA4X, HE HE= harsh environment
Cable, Remote Version:
0 Not used
1 5m/15ft coil and signal cable
2 10m/30ft coil and signal cable
4 ..... m coil and signal cable
5 ..... ft coil and signal cable
9 Special version, TSP-no. to be spec.
Cable Entry:
9 Special version, TSP-no. to be spec.
A Gland M20 (EEx d > thread M20)
B Thread NPT 1/2
C Thread G 1/2
K Bus plug gland M20
L Bus plug thread NPT 1/2
M Bus plug thread G 1/2
Q 2 x Bus plug gland M20
R 2 x Bus plug thread NPT 1/2
S 2 x Bus plug thread G 1/2
Power Supply; Display:
4 HART 7; 85-260VAC; Language ZH PL ID EN; 4-line Touch control
5 HART 7; 20-55VAC /16-62VDC; Language ZH PL ID EN; 4-line Touch control
7 85-260VAC, WEA, w/o display, Remote configuration WEA= language DE EN FR IT ES PT NL
8 20-55VAC / 16-62VDC, WEA, w/o display, Remote configuration WEA= language DE EN FR IT ES PT NL
9 Special version, TSP-no. to be spec.
A 85-260VAC, WEA, 4-line Touch control WEA= language DE EN FR IT ES PT NL
B 20-55VAC / 16-62VDC, WEA, 4-line Touch control, WEA= language DE EN FR IT ES PT NL
C 85-260VAC, SEA, 4-line Touch control SEA= language JA ID EN
D 20-55VAC / 16-62VDC, SEA, 4-line Touch control, SEA= language JA ID EN
E 85-260VAC, EES, 4-line Touch control EES= language SV FI NO RU PL CS EN
F 20-55VAC / 16-62VDC, EES, 4-line Touch control, EES= language SV FI NO RU PL CS EN
G 85-260VAC; CN, 4-line Touch control, CN= language ZH EN
H 20-55VAC / 16-62VDC; CN, 4-line Touch control, CN= language ZH EN
P HART 7; 85-260VAC; Language DE FR IT ES EN; 4-line Touch control
Q HART 7; 20-55VAC /16-62VDC; Language DE FR IT ES EN; 4-line Touch control
R HART 7; 85-260VAC; Language RU NL PT CS EN; 4-line Touch control
S HART 7; 20-55VAC /16-62VDC; Language RU NL PT CS EN; 4-line Touch control
T HART 7; 85-260VAC;Language JA SV NO FI EN; 4-line Touch control
U HART 7; 20-55VAC /16-62VDC; Language JA SV NO FI EN; 4-line Touch control
Adjustment; Software Feature:
A Factory setup; basic version
C Factory setup; ECC electrode cleaning circuit
J Factory setup; Batching
L Factory setup; Batching ECC electrode cleaning circuit
Output, Input:
2 4-20mA SIL HART freq. relay 20mA out, modules exchangeable
4 4-20mA SIL HART freq. relay 20mA in, modules exchangeable
5 4-20mA SIL HART freq. 20mA In stat.In, modules exchangeable
7 Modbus RS485 2x relay stat.In M= modules exchangeable
A 4-20mA SIL HART frequency
B 4-20mA SIL HART freq. 2x relay
C 4-20mA SIL HART freq. 2x relay M= modules exchangeable
D 4-20mA SIL HART freq. relay stat.In, modules exchangeable
H PROFIBUS PA
I EtherNet/IP
J PROFIBUS DP
K FOUNDATION Fieldbus
L 4-20mA SIL HART 2x relay stat.In, modules exchangeable
M 4-20mA SIL HART 2x freq. stat.In, modules exchangeable
N Modbus RS485 20mA freq. stat.In, modules exchangeable
P PROFIBUS DP 20mA freq. stat.In, modules exchangeable
Q Modbus RS485 stat.In
V PROFIBUS DP 2x relay stat.In, modules exchangeable
DK5UI- Electromagnetic Flowmeter 53 Input/Output Module Conversion Assembly
A retrofit kit consists of
instruction sheet
meter documentation, retrofit label
connection
label and the exchangeable I /O modules.
Exist. I /O Modul:
2 4-20mA SIL HART freq. relay 20mA out
4 4-20mA SIL HART freq. relay 20mA in
5 4-20mA SIL HART freq. 20mA In stat.In
7 Modbus RS485 2x relay stat.In
C 4-20mA SIL HART freq. 2x relay
D 4-20mA SIL HART freq. relay stat.In
L 4-20mA SIL HART 2x relay stat.In
M 4-20mA SIL HART 2x freq. stat.In
N Modbus RS485 20mA freq. stat.In
P PROFIBUS DP 20mA freq. stat.In
V PROFIBUS DP 2x relay stat.In
New I /O Modul:
2 4-20mA SIL HART freq. relay 20mA out
4 4-20mA SIL HART freq. relay 20mA in
5 4-20mA SIL HART freq. 20mA In stat.In
7 Modbus RS485 2x relay stat.In
C 4-20mA SIL HART freq. 2x relay
D 4-20mA SIL HART freq. relay stat.In
L 4-20mA SIL HART 2x relay stat.In
M 4-20mA SIL HART 2x freq. stat.In
N Modbus RS485 20mA freq. stat.In
P PROFIBUS DP 20mA freq. stat.In
V PROFIBUS DP 2x relay stat.In
Approval:
A Non-hazardous area
B ATEX
N FM/CSA
DK5WM- Promag10/50/51/53/55 Transmitter Mounting Assembly DK5WM
10/50/51/53/800
Application:
A Remote, wall / pipe mounting, panel
DK5GC- Ground wire DK5GC
A kit includes 2 cables
Nominal Diameter:
15 DN15 1/2"
1F DN150 6"
1H DN100 4"
1Z DN125
25 DN25 1"
2F DN250 10"
2H DN200 8"
32 DN32
3F DN350-DN2000
3H DN300 12"
40 DN40 1-1/2"
50 DN50 2"
65 DN65
80 DN80 3"
Process Connection:
A PN40 EN1092-1(DIN2501)
C PN16 EN1092-1(DIN2501)
D PN1016 EN1092-1(DIN2501)
L Cl. 150 ANSI B16.5
T 10K JIS B2220
U 20K JIS B2220
DK5GD- grounding ring DK5GD
Includes 1 grounding disc/protection
disc
Nominal Diameter:
15A DN15 1/2 ", 1.4435/316L
15B DN15 1/2", Alloy C- 22
15E DN15 1/2", Tantalum
1FA DN150 6 ", 1.4435/316L
1FB DN150 6", Alloy C- 22
1FE DN150 6", Tantalum
1HA DN100 4 ", 1.4435/316L
1HB DN100 4", Alloy C- 22
1HE DN100 4", Tantalum
1ZA DN125, 1.4435/316L
1ZB DN125, Alloy C- 22
1ZE DN125, Tantalum
25A DN25 1 ", 1.4435/316L
25B DN25 1", Alloy C- 22
25E DN25 1", Tantalum
2FA DN250 10 ", 1.4435/316L
2FB DN250 10", Alloy C- 22
2FE DN250 10", Tantalum
2HA DN200 8 ", 1.4435/316L
2HB DN200 8", Alloy C- 22
2HE DN200 8", Tantalum
32A DN32, 1.4435/316L
32B DN32, Alloy C- 22
32E DN32, Tantalum
3FA DN350 14 ", 1.4435/316L
3FB DN350 14", Alloy C- 22
3HA DN300 12 ", 1.4435/316L
3HB DN300 12", Alloy C- 22
3HE DN300 12", Tantalum
40A DN40 1 1/2 ", 1.4435/316L
40B DN40 1 1/2", Alloy C- 22
40E DN40 1 1/2", Tantalum
4FA DN450 18 ", 1.4435/316L
4FB DN450 18", Alloy C- 22
4HA DN400 16 ", 1.4435/316L
4HB DN400 16", Alloy C- 22
50A DN50 2 ", 1.4435/316L
50B DN50 2", Alloy C- 22
50E DN50 2", Tantalum
5HA DN500 20 ", 1.4435/316L
5HB DN500 20", Alloy C- 22
65A DN65, 1.4435/316L
65B DN65, Alloy C- 22
65E DN65, Tantalum
6HA DN600 24 ", 4435/316L
6HB DN600 24", Alloy C- 22
80A DN80 3 ", 1.4435/316L
80B DN80 3", Alloy C- 22
80E DN80 3", Tantalum
999 Special version, TSP-no. to be spec.
Liner:
9 Special version, TSP-no. to be spec.
E PTFE
Process Connection:
9 Special version, TSP-no. to be spec.
A PN40 EN1092-1(DIN2501)
C PN16 EN1092-1(DIN2501)
D PN10 EN1092-1(DIN2501)
E PN6, EN1092-1(DIN2501)
L Cl. 150 ANSI B16.5
T 10K JIS B2220
U 20K JIS B2220
FXA193- communication interface FXA193
The service interface connects
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
-Serviceinterface with RS 232C
connection cable (9 pin.)
-FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
-Service Softw.ToF Tool-Fieldtool
Package
Approval:
9 Special version, TSP-no. to be spec.
A For use in non-hazardous area
B ATEX II (1) GD
C CSA/FM Class I Div. 1
D ATEX, CSA, FM
Connection Cable:
9 Special version, TSP-no. to be spec.
A Proline device
B ToF device
E Proline and ToF device
F Ex two-wire device
G Proline device and Ex two-wire device
H Proline, ToF and Ex two-wire device
X Without connection cable
DK5SO- Promag 53 Software Package DK5SO
Chip for release
software functionality.
Note: The license is locked to a
specific serial number (S-DAT).
Application:
B Batching
C ECC electrode cleaning circiut