Nr 订货号 规格
  71044061 设备包
2x screws, 2x springs, 2x spring rings,
1x sealing CDI-connector
  71367414 铜密封圈
Packing unit: 10 pieces
  71367420 铜密封圈
Packing unit: 10 pieces
  71367424 铜密封圈
Packing unit: 10 pieces
  71367425 铜密封圈
Packing unit: 10 pieces
  71367427 垫片
Packing unit: 10 pieces
D TA20A- **Terminal Head TA20A
Product being phased out,
limited availability.
Connection head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on an
armature or protective sleeve.
Material: Aluminium epoxy resin coating
Area temperature : max. +100 oC;
ATEX: +95 oC.
D TA20B- Terminal Head TA20B
Connecting head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on an
armature or protective sleeve.
Material:Polyamid black.
Ambient temperature: max. +80 oC.
Protection: IP65.
  FXA195- Commubox FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning of
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
  READWIN- Readwin 2000 Operation + Read. software
B TMT180- iTEMP TMT180, Head Transmitter Pt100
Temperature transmitter,PC-programable.
Application: RTD.
2-wire 4-20mA.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
B TMT181- **iTEMP TMT181, Head Transmitter PCP
Product being phased out,
limited availability.
Temperature transmitter,PC-programmable.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanic isolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
  TXU10- Configuration Kit TXU10
for PC-programmable devices.
set-up programme+interface cable for PC
with USB-Port.
B TMT84- iTEMP TMT84, Transmitter PA
Dual sensor input.
Advanced diagnostics:sensor monitoring.
PROFIBUS PA Profile 3.02.
Galvanic isolation 2kV.
Application: RTD, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN EN50446.
Factory setup:
CH1: Pt100, 3-wire, oC.
CH2: inactive.
Differing configuration optional
selectable.
B TMT85- iTEMP TMT85, Transmitter FF
Dual sensor input.
Advanced diagnostics: sensor monitoring.
FOUNDATION Fieldbus protocol
Galvanic isolation 2 kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN EN50446.
Factory setup:
CH1: Pt100, 3-wire, oC.
CH2: inactive.
Differing configuration optional
selectable.
B TID10- Display Unit Head Transmitter
to plug on.
Dot-Matrix measured value display.
12 DIP-switches buttom side.
Settings:
FF: Simulation, Write Lock.
PA: Bus address, Write Lock.
Compatible: TMT85, TMT84, TMT82, TMT71,
TMT72.
D TA30A- Terminal Head TA30A
Retainer for terminal block or head
transmitter + optional display.
Cover: low, hinged, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
D TA30D- Terminal Head TA30D
Retainer for 2 head transmitters or
terminal blocks.
Cover: high, hinged.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
B TMT182- **iTEMP TMT182, Head Transmitter HART
Product being phased out,
limited availability.
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanicisolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
B TMT82- iTEMP TMT82, Transmitter HART
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical
applications by means of SIL 2/3
acc. to IEC61508.