| Accuracy | ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂ ± 10% from 5 - 10 mg/L Cl₂ |
| Air Purge | Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum |
| Alerts | Low and high chlorine. Dirty cell. Low and high sample flow. |
| Certifications | CE compliant with: EN 61326-1, CISPR 11, EN 50581 ACMA RCM South Korea KC Certificate North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003 |
| Controller Compatibility | SC200, SC1000, SC4500. All controllers sold separately |
| Cycle Time | 2.5 minutes |
| Dimensions (H x W x D) | 342 mm x 329 mm x 177 mm |
| Drain | ½-inch ID flexible hose |
| Enclosure Rating | IP66 |
| Inlet | ¼-inch OD polyethylene tube, quick-disconnect fitting |
| Inlet Pressure | 0.3 - 5.2 bar (4.5 - 75 psig) supplied to Y-strainer 0.1 - 0.3 bar (1.5 - 5 psig) supplied to analyzer |
| Installation Kit | Pressure Regulator Installation Kit |
| Interferences | Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃. |
| Light Source | LED, measurement at 510 nm, 1 cm light pathlength |
| Lower Limit of Detection (LOD) | 0.03 mg/L |
| Mounting | Wall mount |
| Operating Humidity | 0 - 90% relative humidity, non-condensing |
| Operating Temperature Range | 5 - 40 °C (41 - 104 °F) |
| Parameter | Chlorine, free; Chlorine, total residual |
| Power Requirements (Voltage) | 12 VDC, 400 mA maximum (supplied by the controller) |
| Range | 0 -10 mg/L Cl₂ |
| Reagent Consumption | 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days |
| Sample Flow Rate | 60 - 200 mL/min through the instrument |
| Sample Requirements | Y-strainer filtration with 40-mesh screen or higher |
| Sample Temperature | 5 - 40 °C (41 - 104 °F) |
| Warranty | 12 months |
| Weight | 4.1 kg (9.0 lbs.) |
| What's included? | CL17sc Chlorine Analyser with Pressure Regulator Installation Kit, and User Manual. User provides screws and/or anchors for mounting. Hach SC Controller and Reagents are not included, they are sold separately. |
服务案例
市政污水处理
市政污水处理污水处理厂 · 哈希应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对哈希的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的哈希,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料
食品饮料食品生产线 · 哈希应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对哈希的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的哈希,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药
化工制药反应釜与储罐 · 哈希应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对哈希的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的哈希,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源
电力能源电厂锅炉与汽机 · 哈希应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对哈希的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的哈希,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。