472104 DIQ/S 281-CR2/24V

472104	DIQ/S 281-CR2/24V

472104 DIQ/S 281-CR2/24V

WTW 472104
Universal Transmitter to operate 1 digital IQ sensor, with 2 x 0(4) … 20 mA, 2 x Relays, for 24 V AC/DC power supply 通用变送器,用于操作1个数字IQ传感器,带2 x 0(4)…20 mA,2 x继电器,用于24 V AC/DC电源

Universal monitor DIQ/S 281. The new system 281 – the digital and cost-efficient single parameter measuring point with proven IQ Sensor Net technology and IQ sensors for the standard parameters. Low-cost alternative to analog measuring points

The System 281 combines the known performance of analog products with the advantages of the digital IQ Sensor Net:

  • Proven and reliable IQ Sensor Net technology
  • 100 % IQ Sensor Net look & feel
  • Versions with analog outputs, Modbus RTU and HART available
  • 2 relays for alarm for main and secondary value
  • You can easily upgrade to DIQ/S 282/284, since IQ sensors can be retained
  • Free software updates with new features
  • Stable, robust and proven measuring technology

Measurement Parameters:

Matching digital IQ sensors for pH/ORPconductivityD.O.turbiditysuspended solids and sludge level (also as seawater version for corrosive media)


Models:

DIQ/S 281-CR2 with power supply via a wide range power supply unit (100-240VAC), 2 analog outputs (0/4-20 mA) and 2 relays
DIQ/S 281-CR2/24V with 24V power supply, 2 analog outputs (0/4-20 mA) and 2 relays
DIQ/S 281-MOD with a wide-range power supply unit (100-240VAC), MODBUS interface (RS 485) and 2 relays
DIQ/S 281-HART with a wide-range power supply unit (100-240VAC) and 2 relays


Made for many applications:

Once developed for wastewater the IQ Sensor Net is also successfully applied in drinking water applications and the process industry for many years. Try it yourself! Some examples:

  • With SensoLyt® 700 IQ for different pH ranges in drinking water
  • With VisoTurb® 700 IQ, the turbidity sensor with ultrasonic cleaning in the wwtp outlet
  • With the calibration free dissolved oxygen sensor FDO® 700 IQ in the aeration basin
  • With TetraCon® 700 IQ, the 4 electrode conductivity cell in the process industry
  • With the suspended solids sensor ViSolid® 700 IQ with ultrasonic cleaning in the aeration basin of a wwtp with industrial wastewater
  • With IFL 700 IQ, the ultrasonic sensor for detailed presentation of sludge profile in the post-sedimentation
Controller DIQ/S 281-CR2 DIQ/S 281-CR2/24V DIQ/S 281-MOD DIQ/S 281-HART
Order No. 472103 472104 472105 472106
Icon: CE Product Certification for Xylem Analytics Products   Icon: UKCA Product Certification for Xylem Analytics Products   Icon: Xylem Analytics Products that is cETLus listed by Intertek       detailed technical data see data sheet D1.09
Max. number of sensors 1
Connectable sensors IQ sensors for pH/ORP, O2, conductivity, turbidity, TSS or sludge level
Communication 2 x (0) 4–20 mA2 x relays Modbus RTU
2 x relays
HART
2 x relays
Cable length sensor 100 m fixed cable
Max. total cable length 250 m
Power supply Wide range mains converter (100-240VAC) 24V Wide range mains converter (100-240VAC)
Connectable modules DIQ/CHV (Cleaning Head Valve), DIQ/JB and MIQ/WL PS SET