Nr Order Number Specifications
31 71323007 Power Module
Usage:
Promag/Promass 300/500
Prosonic Flow/t-mass 300
transmitter housing
electronic compartment.
31 71323008 Power Module
Usage:
Promag/Promass 300/500
Prosonic Flow/t-mass 300
transmitter housing
electronic compartment.
31 71323009 Power Module
Usage:
Promag/Promass/Prosonic Flow/
t-mass 300/500 digital
Non-haz, Zone 2
transmitter housing
electronic compartment.
33 XPD0052- ISEM electronic plug-in, t-mass 300/500
Usage:
t-mass 300/500 digital.
Valid for approvals acc. feature 010.
ISEM module V305-02.
AA
1A
00
39 71185788 T-DAT module
33 XPD0053- ISEM electr.mod., t-mass 300
Usage:
t-mass 300
Valid for approvals acc. feature 010.
ISEM module V305-01.
AA
1B
00
37 71323010 module box, 300/500, Ex
Usage:
transmitter housing
electronic compartment.
Consists:
module cartridge incl.
interconnection board.
34 XPD0037- I/O Modules
Usage:
Proline 300/500
AA
A1
B1
F1
H1
01
37 71323011 Module Box, 300, Non-haz
Usage:
transmitter housing
electronic compartment.
Consists:
module cartridge incl.
interconnection board.
46 71323005 Ribbon Cable Assembly
Usage:
Promag/Promass 300/500, t-mass 300
transmitter housing.
35 XPD0038- I/O Modules
Usage:
Proline 300/500
AA
1A
1B
1D
00
45 71323073 Terminal Assembly
Usage:
transmitter housing Alu/hygienic
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists:
1x connection terminal 2-Pol .,
1x connection terminal 3-Pol .,
1x connection terminal 4-Pol.
50 XPD0031- Display Module
Usage:
Proline 300/500, DKX001.
AA
DA
0
F
G
00
45 71327818 Terminal Assembly
Usage:
transmitter housing Alu/hygienic
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists:
1x connection terminal 2-Pol .,
1x connection terminal 3-Pol .,
1x connection terminal 4-Pol.
45 71323075 Terminal Assembly
Usage:
transmitter housing Alu/cast
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists:
2x connection terminal 2-Pol .,
1x connection terminal 4-Pol.
45 71327819 Terminal Assembly
Usage:
transmitter housing Alu/cast
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists:
2x connection terminal 2-Pol .,
1x connection terminal 4-Pol.
49 71323079 Terminal Assembly
Usage:
transmitter housing Alu/cast
connection compartment
with remote display DKX001.
Consists:
1x connection terminal 4-Pol.
20 71323016 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Prosonic Flow 500
transmitter housing Alu, Non-haz.
Promag/Promass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover sight glass, Alu
O-Ring 110.7x3.53 HNBR.
20 71323017 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Non-haz.
Promass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover sight glass, Alu
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
21 71323018 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Non-haz.
Promag/Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 110,7x3,53 HNBR.
21 71323019 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Non-haz.
Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
20 71323020 Aluminum Cover Assembly Glass Window
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover sight glass, Alu
O-Ring 110.7x3.53 HNBR.
20 71323021 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover sight glass, Alu
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
21 71323022 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 110,7x3,53 HNBR.
21 71323023 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
70 71323026 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu/cast.
Consists:
10x O-Ring 110.7x3.53 HNBR.
70 71323027 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu/cast
Consists:
O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
22 71323028 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Prosonic Flow 500
transmitter housing Alu, Non-haz.
Consists:
cover Alu
O-Ring 117,1x3,53 HNBR.
22 71323029 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Prosonic Flow 500
transmitter housing Alu, Non-haz.
Consists:
cover Alu
O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
74 71323030 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Prosonic Flow 500
transmitter housing Alu, Non-haz.
Consists:
10x O-Ring 117,1x3,53 HNBR.
74 71323031 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Prosonic Flow 500
transmitter housing Alu, Non-haz.
Consists:
O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
22 71323032 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 120,2x3,53 HNBR.
22 71323033 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu, Ex.
Consists:
cover Alu
O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
74 71323036 Cover Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu/cast, Ex.
Consists:
10x O-Ring 120,2x3,53 HNBR.
74 71323037 Cover Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing Alu/cast, Ex.
Consists:
O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
28 71323044 Cover Assembly
Usage:
Remote display DKX001
housing Alu.
Consists:
cover Alu
O-Ring 88,50x3,53 HNBR.
28 71323045 Cover Assembly
Usage:
Remote display DKX001
housing Alu.
Consists:
cover Alu
O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
76 71323048 Cover Assembly
Usage:
Remote display DKX001
housing Alu/cast.
Consists:
10x O-Ring 88,50x3,53 HNBR.
76 71323049 Cover Assembly
Usage:
Remote display DKX001
housing Alu/cast.
Consists:
O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
71 71323071 Interface Seal Ring Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promass/Prosonic Flow 500
transmitter housing/sensor or
transmitter housing/wall mount.
Consists:
5x O-Ring 88,50x3,53 HNBR
interface.
71 71323072 Interface Seal Ring Assembly
Usage:
Promass/Prosonic Flow/t-mass 300
Promass/Prosonic Flow 500
transmitter housing/sensor or
transmitter housing/wall mount.
Consists:
O-Ring 88,50x3,53 FVMQ
interface, -50oC/-58oF.
11 71368488 protective shell
Usage:
transmitter housing Alu/hygienic
connection compartment.
Option A =
HART, PROFIBUS PA, PROFIBUS DP
Modbus RS485, FOUNDATION Fieldbus.
Consists:
Connection compartment protective cover
display carrier, 2x screw M4x10.
11 71323081 Protective Cap Assembly
Usage:
transmitter housing Alu/cast
connection compartment.
Option A =
HART, PROFIBUS PA, PROFIBUS DP
Modbus RS485, FOUNDATION Fieldbus.
Consists:
Connection compartment protective cover
display carrier, 2x screw M4x10.
71450720 adapter M12,RJ45, L = 175mm (for t-mass F 300, I
Usage:
Proline 300/500.
87 71343505 Protective Enclosure Assembly
Usage:
Promag/Promass/Prosonic Flow/t-mass 300
Promag/Promass/Prosonic Flow 500
transmitter housing.
Consists:
weather protection cover 4404
installation material.
71351317 wireless receiver reaches extended distance
Consists:
Connection cable in the transmitter
Ex cable entry for antenna
1.5m cable
antenna
angle with union nut.
6X3BXX- Transmitter t-mass 300, 6X3BXX
With an integrated web server.
AA
BB
BD
BS
C2
C4
CD
CS
CZ
GB
GD
GR
GS
JD
KD
MB
MD
MS
NB
ND
NS
UB
UD
UR
US
9
D
E
I
99
BA
CA
CC
MA
9
A
B
C
D
E
G
H
I
J
9
A
B
C
D
E
G
H
I
J
9
A
F
G
M
O
9
A
6
9
A
B
C
D
IA
99
HA
SA
SB
SC
A2
I7
I9
JP
K9
N9
NB
P8
PB
R9
RA
76
78
Z1
Z2
DKX001- Remote Display DKX001
Remote display and operating
module of Proline 300
For more installation flexibility
and better readability.
Delivery:
Depends on the selection in
the indvidual product structure.
AA
BE
BS
CE
CI
CS
CZ
GE
GR
GS
JE
KE
ME
MS
NE
NS
UE
UR
US
9
A
F
9
B
C
1
9
A
B
D
E
9
A
B
C
D
I7
I9
JN
K9
L9
R9
RA
Z1
DKX002- Remote Display Connection Cable
Connection Cable for Remote Display
DKX001 of Proline 300.
AA
BE
BS
CE
CI
CS
CZ
GE
GR
GS
JE
KE
ME
MS
NE
NS
UE
UR
US
9
A
B
D
E
DK6ML- Plug-in valve mounting assembly DK6ML
For insertion sensors.
Retraction of sensor at atmospheric
pressure. Process isolation with ball
valve.
Max. process pressure: 20 bar / 290 psi
9
A
B
C
D
1
2
5
7
9
9
A
DK6003- online replacement kit with pressure
Usage:
t-mass 6I3B, 6I5B, 6BAB, 6TAB.
Insertion and withdrawal of sensor
under pressure without process
interruption.
PG
PH
PI
PJ
PK
PL
PM
PN
99
AA
BA
DA
DB
DC
DD
DE
99
AA
AB
AC
DF
NA
NB
JA
PA
PB
PC
PD
PF
DK6004- Flow Equalizer
Usage:
t-mass I 300/500
-200oC... 400oC / -330... 750oF
1F
1H
2F
2H
3H
80
99
AA
AB
DA
DB
DC
DD
NA
NB
0
9
JA
XPRFID- Spare RFID TAG
Consists:
RFID TAG, fixing wire, crimp sleeve.
AA
BA
CA
IA
KA
MA
NA
UA
UR
1