Nr Order Number Specifications
71044061 Device Pack
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector
TXU10- Instrument debugging package TXU10
for PC-programmable devices
Program settings + connection line for PC with USB interface
Version:
AA 4 pin plug + ReadWin2000
TMT180- module temperature transmitter TMT180
Temperature transmitter,PC-programable.
Application: RTD.
2-wire 4-20mA.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
Approval:
A Non-hazardous area
Programming:
1 Via PC
2 Blocked
Measuring Range; Accuracy:
1 -200...650oC; 0.2K / 0,08% span
2 -50...250oC; 0.1K / 0,08% span
Configuration Connection:
3 RTD 3-wire
4 RTD 4-wire
Configuration Range:
XX See additional spec., min span 10K
Additional Option:
A Standard - DIN mounting set
TMT181- module temperature transmitter TMT181
Temperature transmitter,PC-programmable.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, galvanic isolation.
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN EN50446.
UL listed.
Approval:
A Non-hazardous area
B ATEX II1G Ex ia IIC T4/T5/T6
I FM+CSA IS,NI,Class I ,Div.1+2,Group ABCD
Configuration Connection:
3 RTD 3-wire
4 RTD 4-wire
Configuration Sensor Type:
1 Pt100, -200...850oC, min. span 10K, IEC751 (a = 0,00385)
Configuration:
B Measuring range, see additional spec.
Additional Option:
A Standard - DIN mounting set
TMT84- module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring.
Galvanic isolation 2kV.
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
Factory setup:
CH1: Pt100, 3-wire, oC
CH2: inactive
Differing configuration optional
selectable.
Approval:
A1 Non-hazardous area
B1 ATEX II1G Ex ia IIC T4/T5/T6
Output Signal:
A PROFIBUS PA
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
A W/o, mounting set DIN standard
>Configuration Input:
B1 Ch1: RTD 3-wire, Ch2: inactive
C1 Ch1: RTD 4-wire, Ch2: inactive
TMT85- module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics
for sensor monitoring.
FOUNDATION Fieldbus protocol (ITK 5.0).
Galvanic isolation 2 kV
(sensor input to the output).
Application: RTC, TC, Ohm, mV.
Current consumption: 11 mA.
Mounting: head form B, DIN43729.
UL listed, CSA General Purpose.
Approval:
A1 Non-hazardous area
B1 ATEX II1G Ex ia IIC T4/T5/T6
Output Signal:
A FOUNDATION Fieldbus H1
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
A W/o, mounting set DIN standard
>Configuration Input:
B1 Ch1: RTD 3-wire, Ch2: inactive
C1 Ch1: RTD 4-wire, Ch2: inactive
FXA195- communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning
field devices with software tool.
:: To connect to a intrinsically safe
signal circuit.
:: SIL2, IEC61508.
Approval:
G ATEX II (1)GD [EEx ia] IIC
Additional Option:
1 Basic version
READWIN- Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
Memory Medium:
1 CD
Software:
AA E H
TA20A- **Junction box TA20A
Product being phased out
limited availability.
Connection head to mount a measuring
insert with head transmitter or a
connection socket. To be mounted on
armature or protective sleeve.
Material: Aluminium epoxy resin coating
Area temperature : max. 100 oC;
ATEX: 95 oC.
Thermometer Connection:
A M24x1.5
Cable Entry:
5 Gland M20
Colour:
A Housing blue, cap grey
Labelling:
1 Standard E H
TA30A- lug TA30A
Retainer for terminal block or head
transmitter optional display.
Cover: low, hinged, optional window.
Material: aluminium.
Coating: polyester powder-coating.
Colour: body blue, cover grey.
Ambient temp.: -50...150 oC (housing).
Protection: IP66/68, NEMA 4X (housing).
Connection Protection Tube Assembly:
1 Thread M24x1.5
Electrical Connection:
A 1x thread M20x1.5
C 1x thread G1/2
Display window:
1 W/o
>Cable Gland; Temp.Range; Protect. Type:
A1 1x Polyamide; -40... 100oC; IP68
A2 1x Polyamide ATEX; -20... 95oC; IP68 für dust-Ex
A3 1x brass ATEX; -20... 130oC; IP68, NEMA 4X for dust Ex
TMT182- module temperature transmitter TMT182
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV.
2-wire 4-20mA, SIL2, galvanic isolation
Fault reaction: NAMUR NE 43.
Mounting: head form B, DIN43729.
UL listed.
GL (German Llyod) Marine.
Approval:
A Non-hazardous area
B ATEX II1G Ex ia IIC T4/T5/T6
I FM CSA IS,NI,Class I ,Div. 1 2,Group ABCD
Configuration Connection:
E RTD 3-wire, non-SIL
F RTD 4-wire, non-SIL
Configuration Sensor Type:
1 Pt100, -200...850oC, min. span 10K, IEC751 (a = 0,00385)
Configuration:
B Measuring range, see additional spec.
Additional Option:
A Standard - DIN mounting set
B TMT82- module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input.
Galvanic isolation 2kV (input/output).
Application: RTD, TC, Ohm and mV.
::Highly reliable due to drift
detection and sensor back up.
::Optional also for safety critical applications
by means of SIL 2/3 acc. to IEC61508.
Approval:
8C FM CSA IS, NI I /1 2/A-D
AA Non-hazardous area
BA ATEX II1G Ex ia IIC T4/T5/T6
Communication; Output Signal:
A HART; 1x 4-20 mA
Electrical Connection:
1 Spring terminals, housing form B, DIN EN 50446
2 Screw terminals, housing form B, DIN EN 50446
Field Housing:
A W/o, mounting set DIN standard
Configuration Universal Input:
B1 Ch1: RTD 3-wire, Ch2: inactive
C1 Ch1: RTD 4-wire, Ch2: inactive
Sensor Type Input 1:
A1 Pt100, -200...850oC, min. span 10K, IEC60751 (a = 0.00385)
Sensor Type Input 2:
AA Inactive
Input; Interconnection:
A1 PV = CH1; CH2 inactive
>>Additional Approval:
LA SIL conformity