| Nr | Order Number | Specifications | |||||||||||||||||||||||||||||||||||||||||||||
| 71044061 | Device Pack
2x screws, 2x springs, 2x spring rings
1x sealing CDI-connector |
||||||||||||||||||||||||||||||||||||||||||||||
| TXU10- | Instrument debugging package TXU10
for PC-programmable devices
Program settings + connection line for PC with USB interface
|
||||||||||||||||||||||||||||||||||||||||||||||
| TMT180- | module temperature transmitter TMT180
Temperature transmitter,PC-programable.
Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
|
||||||||||||||||||||||||||||||||||||||||||||||
| TMT181- | module temperature transmitter TMT181
Temperature transmitter,PC-programmable.
Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
|
||||||||||||||||||||||||||||||||||||||||||||||
| TMT84- | module temperature transmitter TMT84
Dual sensor input.
Advanced diagnostics: sensor monitoring. Galvanic isolation 2kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. Factory setup: CH1: Pt100, 3-wire, oC CH2: inactive Differing configuration optional selectable.
|
||||||||||||||||||||||||||||||||||||||||||||||
| TMT85- | module temperature transmitter TMT85
Temperature transmitter with dual
sensor input and advanced diagnostics for sensor monitoring. FOUNDATION Fieldbus protocol (ITK 5.0). Galvanic isolation 2 kV (sensor input to the output). Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN43729. UL listed, CSA General Purpose.
|
||||||||||||||||||||||||||||||||||||||||||||||
| FXA195- | communication interface FXA195
Modem to connect HART field devices
to a computer via USB. Commissioning field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
|
||||||||||||||||||||||||||||||||||||||||||||||
| READWIN- | Readwin 2000 Debug Package READWIN
Readwin 2000 Operation Read. software
|
||||||||||||||||||||||||||||||||||||||||||||||
| TA20A- | **Junction box TA20A
Product being phased out
limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. 100 oC; ATEX: 95 oC.
|
||||||||||||||||||||||||||||||||||||||||||||||
| TA30A- | lug TA30A
Retainer for terminal block or head
transmitter optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
|
||||||||||||||||||||||||||||||||||||||||||||||
| TMT182- | module temperature transmitter TMT182
Temperature transmitter, Protocol HART.
Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanic isolation Fault reaction: NAMUR NE 43. Mounting: head form B, DIN43729. UL listed. GL (German Llyod) Marine.
|
||||||||||||||||||||||||||||||||||||||||||||||
| B | TMT82- | module temperature transmitter TMT82
2-wire temperature transmitter.
Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
|
|||||||||||||||||||||||||||||||||||||||||||||