Technical Data
ComparepH
| Measuring Principle | |
| Application | Hygienic and sterile applications, process |
| Characteristic | CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside - version upside-down installation available - pressurized reference (6 bar) Pt-disc as additional ORP element. rH measurment and control of the reference impedance. |
| Measuring range | pH 0-14 |
| Measuring principle | - ceramic diaphragm - Ion trap |
| Design | - All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology |
| Material | glass / ceramic |
| Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16,57 inch) |
| Process temperature | -15°C ... 140°C (5°F - 284°F) |
| Process pressure | max. 13 bar (188 psi)depends on selected version |
| Temperature sensor | NTC 30k |
| Connection | Inductive, digital connection head with Memosens technology. |
| Ingress protection | IP68 |
pH:
| Measuring Principle | Potentiometric | |
| Application | Hygienic and sterile applications, process | |
| Characteristic | CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside - version upside-down installation available - pressurized reference (6 bar) Pt-disc as additional ORP element. rH measurment and control of the reference impedance. | |
| Measuring range | pH 0-14 | |
| Measuring principle | - ceramic diaphragm - Ion trap | |
| Design | - All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology | |
| Material | glass / ceramic | |
| Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16,57 inch) |
|
| Process temperature | -15°C ... 140°C (5°F - 284°F) |
|
| Process pressure | max. 13 bar (188 psi)depends on selected version |
|
| Temperature sensor | NTC 30k | |
| Connection | Inductive, digital connection head with Memosens technology. | |
| Ingress protection | IP68 | |
Case Studies
市政污水处理
市政污水处理污水处理厂 · ORP应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料
食品饮料食品生产线 · ORP应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药
化工制药反应釜与储罐 · ORP应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源
电力能源电厂锅炉与汽机 · ORP应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对ORP的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的ORP,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。