Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FTL51H 音叉限位检测开关

FTL51H 音叉限位检测开关

音叉限位检测开关

Configurable Models 4 models
Liquiphant FTL51H is a point level switch with extension tube for use in hazardous areas with all international certificates. Especially useable in the food and life sciences industry with hygienic certificates (3-A, EHEDG, ASME BPE). FTL51H offers functional safety SIL2/SIL3. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

The Liquiphant FTL51H vibronic point level switch with extension tube can be used in hazardous areas and has various international approvals. With hygienic certifications such as 3-A, EHEDG and ASME BPE, it is especially suitable for the food and life sciences industries. The FTL51H achieves SIL2/SIL3 functional safety, and the second line of defense ensures the highest degree of device safety and availability. The measured value is stable and unaffected by flow, turbulence, bubbles, foam, vibration, solids content or buildup.

 

Benefits

Suitable for safety systems requiring SIL2/SIL3 functional safety, in accordance with IEC 61508/IEC 61511-1

Various process connections available

Various electronic inserts, such as NAMUR, relay, semiconductor thyristor, PFM signal output, for connection to various process control systems

Also available with PROFIBUS PA communication protocol

No calibration required: fast and economical device startup

No mechanical moving parts, no maintenance, no wear and a long service life. Fork damage can be monitored to ensure proper function

FDA-listed material (PFA Edlon)

 

Application areas

Limit switch with electropolished surface, for detection of all types of liquids.

Process connection: thread, flange and hygienic connections (clamp, milk coupling, aseptic, DRD, SMS, Varivent)

Temperature: -50 ~ +150 °C (-58 ~ +302 °F)

Pressure: -1 ~ +64 bar (-14.5 ~ +928 psi)

Sensor material: 316L

International explosion protection approval, WHG overflow protection, SIL, hygienic approval, marine approval

 

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Compare

Density

Measuring Principle Vibration Density
Characteristic / Application Premium device for density measurement in hygienic/aseptic applications.
Focus Food & Beverage and Life Sciences.
Sensor with pipe extension up to 3 m (9,85 ft).
Modular housing or completely welded compact housing.
Wide range of certificates.
Supply / Communication via density controller FML621
Ambient temperature -40 °C...70 °C (-40...158 °F)
Process temperature 0...80 °C (32…176 °F)
Process pressure 0...25 bar (0…362 psi)
Wetted parts 316L
Hygienic 3A
EHEDG
Sensor length Short tube (Liquiphant II)
148mm…3000mm (6,00…118")
Output Pulse
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
Specialities Density/Concentration measurement in combination
with density controller FML621,
Surface finish: mechanical polished (up to 0.3 µm)
Components Density Computer FML621

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application Premium device for point level detection
in hygienic/aseptic applications.
Focus Food & Beverage and Life Sciences.
Pipe extension up to 3 m (9,85 ft).
Modular & completely welded housing concept,
Wide range of certificates.
Specialities Plug and play functionalities,
Surface finish: mechanical or electro-polished,
Density/Concentration measurement,
SIL 2/3 according to IEC 61508
Supply / Communication PROFIBUS PA,
19 ..253V AC,
10...55V DC-PNP,
19...253V AC or 19...55V DC with relay DPDT,
8/16mA,
NAMUR,
PFM
Ambient temperature -50 °C...+70 °C
(-58 °F...+158 °F)
Process temperature -50 °C...+150 °C
(-58 °F...+302 °F)
Process pressure / max. overpressure limit Vacuum...64 bar
(Vacuum...928 psi)
Min. density of medium 0.5g/cm³
(0.4g/cm³ optional)
Main wetted parts 316L
Process connection Threads (for weld-in adapter):
G3/4A, G1A,
Flange:
DN25...DN100,
ASME 1"...4",
JIS 25A...100A
Process connection hygienic Tri-Clamp,
DIN 11851, DIN11864-1
Ingold,
Flush mount,
DRD,
SMS1145,
Varivent (Varinline)
Sensor length Short tube (Liquiphant II)
148mm…3000mm (6,00…118")
Communication PROFIBUS PA
Certificates / Approvals ATEX, IEC Ex, FM, CSA C/US, TIIS,
INMETRO Ex, NEPSI Ex
Safety approvals Overfill protection WHG,
SIL 2/ SIL 3
Design approvals Inspection certificate 3.1, EN10204,
CoC ASME BPE,
Conformity to cGMP,
EU Food Contact Material (EC) 1935/2004,
US Food Contact Material FDA CFR 21,
CN Food Contact Material GB 4806,
Declaration of Conformity ASME B31.3,
AD2000,
CRN approval
Hygienic approvals 3-A,
EHEDG,
CoC-ASME BPE
Marine approval GL/ ABS/ DNV
Options Customized settings (Density)
Components FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR
Successor FTL63
Model Name
FTL51H-ATE2BC2G6A 音叉限位检测开关
FTL51H-EEE2DC2G7A 音叉限位检测开关
FTL51H-GTE2BC5G6C 音叉限位检测开关
FTL51H-GTE2DCDN6A 音叉限位检测开关
市政污水处理

市政污水处理污水处理厂 · 音叉应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 音叉应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 音叉应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 音叉应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对音叉的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的音叉,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。