Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FMR60 雷达液位计

FMR60 雷达液位计

雷达液位计

Configurable Models 2 models
Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.

Micropilot FMR60 is the first 80 GHz radar designed in accordance with the IEC 61508 international functional safety standard. The non-contact radar uses a droplet antenna, improved algorithms and a small beam angle for maximum reliability. It enables non-contact continuous level measurement of liquids, pastes and sludge. The measurement result is unaffected by changes in the medium, temperature fluctuations, gas phase layer or vapor. In addition, it is equipped with Heartbeat Technology intelligent sensor functions.

 

Benefits

Hardware and software designed in accordance with IEC 61508, achieving maximum safety SIL3 in redundant systems

Heartbeat Technology ensures economical and safe operation of the device throughout its entire life cycle

The HistoROM data management concept enables fast and simple commissioning, maintenance and diagnostics

Small beam angle and multi-echo tracking algorithm ensure maximum reliability of measurement in vessels with internal obstacles

The 80 GHz radar can be integrated into the process more conveniently, reducing design effort

The innovative droplet antenna is made of PTFE for maximum system suitability

The world's simplest SIL proof test concept, along with WHG, saving time and costs

 

Application

The 80 GHz droplet antenna can measure in free space with a maximum range of 50 m, has a highly focused beam angle and is suitable for applications with multiple obstructions in the vessel.

Process connection: thread or flange

Temperature: -40...+130°C (-40...+266°F)

Pressure: –1...+16 bar (–14.5...+232 psi)

Measuring range: Max. 50 m (164 ft)

Measuring accuracy: ±1 mm (0.04 in)

W-band: 80 GHz

International explosion protection certificates, WHG overflow protection approval, SIL, marine approval, 5-point linearity protocol

 

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

   

Measuring Principle Video

Source:Endress+Hauserwebsite public information

Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application For basic level measurement in liquids, pastes and slurries;
non affected by changing media, temperature changes, gas blankets or vapor;
For applications with many obstacles due to the very small beam angle.
Specialities Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
Safety and reliability with Multi-Echo Tracking
HistoROM
RFID TAG for easy identification
Supply / Communication 2-wire (HART)
Bluetooth® wireless technology and App (optional)
Frequency W-band (~80 GHz)
Accuracy +/- 1 mm (0.04 in)
Ambient temperature -40…+80 °C
(-40…+176 °F)
Process temperature -40…+130 °C
(-40…+266 °F)
Process pressure / max. overpressure limit Vacuum …16 bar
(Vacuum … 232 psi)
Main wetted parts PTFE antenna
PP or 316L process connections
Process connection Thread:
G1-1/2", MNPT1-1/2";
Flange:
UNI DN80…DN150 (3"…6")
Max. measurement distance 50 m (164 ft)
Communication 4…20 mA HART,
Additional switch,
Bluetooth® wireless technology
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
Safety approvals Overfill protection WHG
SIL 2, SIL 3
Design approvals EN 10204-3.1
Options Display,
Customized parameterization,
Remote operation via SmartBlue App using Bluetooth®,
Gas-tight feed through,
PWIS free
Application limits Process temp. > 130 °C (266 °F) -> FMR62
Very aggressive media -> FMR62
Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x
Model Name
FMR60-AAAAAAGAY9GGJAAEJNC 雷达液位计
FMR60-AAACAAGAB4GGJ+AK 雷达液位计
市政污水处理

市政污水处理污水处理厂 · 雷达应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 雷达应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 雷达应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 雷达应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对雷达的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的雷达,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。