放射线物位和密度测量
The Gammapilot FMG50 compact transmitter performs non-contact limit detection, continuous level measurement, interface measurement and density measurement in liquids, solids, suspensions or sludge. It is the first two-wire loop-powered compact transmitter, minimizing design and installation workload.
Benefits
A true two-wire loop-powered compact transmitter that minimizes design and installation workload
The first two-wire loop-powered compact transmitter, saving installation and design costs
Increased safety, efficiency and stability even under extreme process and environmental conditions
Designed in accordance with IEC 61508, fully meeting the measurement requirements of SIL2/3 applications
Advanced Heartbeat Technology reduces verification workload and minimizes device downtime
Innovative sensor technology for ambient temperatures up to +80°C (+176°F) without cooling
Bluetooth® wireless technology for remote operation outside the beam radiation range
Applications
Suitable for all types of process vessels, e.g. reactors, autoclaves, separation tanks, acid tanks, cyclones
Suitable for measuring media such as liquids, solids, suspensions or sludge
Suitable for extreme conditions, e.g. corrosive, abrasive, viscous or toxic media
Process temperature: unrestricted (non-contact measurement)
Process pressure: unrestricted (non-contact measurement)
Housing materials: 316L, aluminum
International explosion-protection approval, SIL certification and WHG overflow protection
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Technical Data
CompareContinuous / Liquids
| Measuring Principle | Radiometric |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Interface measurement | Interfaces liquid / liquid also with emulsion layers Interfaces liquid / solid |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Accuracy | +/-1% |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode |
| Max. measurement distance | Unlimited measuring range, Cascade |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Continuous / Solids
| Measuring Principle | Radiometric |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Accuracy | +/-1% |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator 400 mm...3000 mm, >3000 mm cascade mode |
| Max. measurement distance | Unlimited measuring range, Cascade |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Density
| Measuring Principle | Radiometric Density |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure | Any |
| Wetted parts | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Output | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Options | Display |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Point Level / Liquids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Point Level / Solids
| Measuring Principle | Radiometric Limit |
| Characteristic / Application | Compact transmitter for extreme process conditions (temperature, pressure); Non-contact measuring technique |
| Specialities | Heartbeat Technology, SIL 2/3 according to IEC 61508, Bluetooth® commissioning, operation and maintenance with the SmartBlue App |
| Supply / Communication | 2-wire loop powered |
| Ambient temperature | -40 °C...+80 °C, (-40 °F...+176 °F) |
| Process temperature | Any |
| Process pressure / max. overpressure limit | Any |
| Main wetted parts | Non-contact |
| Process connection | Non-contact |
| Sensor length | PVT scintillator: 200 mm...400 mm, NAI scintillator: 50 x 50 mm, 50 x 100 mm |
| Communication | 4...20 mA HART |
| Certificates / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex |
| Safety approvals | Overfill protection WHG SIL 2/3 |
| Design approvals | EN 10204-3.1 |
| Options | Display |
| Components | Isotope: FSG60, FSG61, Source container: FQG60, FQG61, FQG62, FQG63, FQG66, Mounting accessories: FHG61 |
Related Models
Case Studies
市政污水处理污水处理厂 · 放射性应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对放射性的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 放射性应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对放射性的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 放射性应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对放射性的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 放射性应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对放射性的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。