Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FQG63 Gamma射线仪表源盒

FQG63 Gamma射线仪表源盒

射线仪表源盒

The FQG63 source container is designed to hold the radioactive source during radiometric level, density and interface measurement. The radiation is damped in all directions as long as the source container is switched off. This guarantees highest safety for the personnel and a reliable measurement. If the source is switched on and lowered down into the process tank, it emits the radiation into all directions.
Compare

Continuous / Liquids

Measuring Principle Radiometric
Characteristic / Application Source container with flexible extension element to position the source inside the process vessel (diptube)
Approximately 87kg
Adapter flange: 10kg
Specialities With flexible extension element
Ambient temperature -52 °C...+200 °C
(-61 °F...+392 °F)
Process temperature max. 400°C (752°F)
Process pressure / max. overpressure limit Any (diptube)
Main wetted parts Non-contact
Process connection Non-contact

Continuous / Solids

Measuring Principle Radiometric
Characteristic / Application Source container with flexible extension element to position the source inside the process vessel (diptube)
Approximately 87kg
Adapter flange: 10kg
Specialities Control area calculation with Applicator
Ambient temperature -52 °C...+200 °C
(-61 °F...+392 °F)
Process temperature max. 400°C (752°F)
Process pressure / max. overpressure limit Any (diptube)
Main wetted parts Non-contact
Process connection Non-contact

Density

Measuring Principle Radiometric Density
Characteristic / Application Source container with flexible extension element to position the source inside the process vessel (diptube)
Approximately 87 kg
Adapter flange: 10 kg
Ambient temperature -52 °C...+200 °C
(-61 °F...+392 °F)
Process temperature max. 400°C (752°F) (diptube)
Process pressure Any
Wetted parts Non-contact
Hygienic Non-contact
Specialities Control area calculation with Applicator

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Source container with flexible extension element to position the source inside the process vessel (diptube)
Approximately 87kg
Adapter flange: 10kg
Specialities Control area calculation with Applicator
Ambient temperature -52 °C...+200 °C
(-61 °F...+392 °F)
Process temperature max. 400°C (752°F) (diptube)
Process pressure / max. overpressure limit Any (diptube)
Main wetted parts Non- contact
Process connection Non- contact

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Source container with flexible extension element to position the source inside the process vessel (diptube)
Approximately 87kg
Adapter flange: 10kg
Specialities Control area calculation with Applicator
Ambient temperature -52 °C...+200 °C
(-61 °F...+392 °F)
Process temperature max. 400°C (752°F)
(diptube)
Process pressure / max. overpressure limit Any (diptube)
Main wetted parts Non- contact
Process connection Non- contact
Process connection hygienic Non- contact

The FQG63 source container holds a radioactive source and is used for radiometric level, density and interface measurement. When the source container is closed, radiation is shielded in all directions, ensuring maximum personal safety and reliable measurement. When the source container is open and placed inside the process vessel, radiation is emitted in all directions.

Advantages
Nearly spherical design; the lightweight source container provides optimum shielding
Meets the highest safety class (DIN 25426/ISO 2919, typical classification C66646)
Flexible installation length, up to 30 m (98 ft)
Manual operation
Switch position secured by padlock or safety bolt
Easy identification of switch status
Integrated source container for simple installation, with adapter and centering flange for existing vessel flanges

Application
The FQG63 source container is used to house the radioactive source during radiometric limit detection and level, density and interface measurement. In the closed position the source is held in the container and the radiation path is closed. In the open position the source with its movable extension rod is placed in the protective pipe of the process vessel.

 

E+H Product Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the boxes below (max. three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 放射性应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 放射性应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 放射性应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 放射性应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对放射性的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的放射性,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。