Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CYP03D Digital Simulator

CYP03D Digital Simulator

数字模拟器

Comprehensive Memosense measurement point inspection, applicable to all industries
Compare

Conductivity

Measuring Principle Conductive
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Umgebungstemperatur: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Disinfection

Measuring Principle Free chlorine
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Connection Battery powered

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX: Ex ia, zone 0
Connection Battery powered
Ingress protection IP65

Turbidity

Measuring Principle Single beam scattered light
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol.
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling.
Measuring range Ranges like the simulated sensors.
Dimension Handheld, 9,5 x 23,5 x 3,5 cm
Process temperature -20...55°C ambient temperature
Ex certification ATEX: Ex ia, zone 1
Connection Battery powered
Ingress protection IP65

pH

Measuring Principle Potentiometric
Application Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Installation Temporary connection via Memosens cable with inductive coupling
Measuring range Ranges like the simulated sensors
Dimension Handheld:
94 x 236 x 40 mm
3.7 x 9.29 x 1.57 inch
Process temperature Ambient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certification ATEX, IECEx, CSA
Connection Battery powered
Ingress protection IP65

Memocheck Sim CYP03D is a flexible service and certification tool for all applications. It simulates definable values to support your installation, debugging, and troubleshooting. Memocheck Sim can replace the sensor, check the complete measurement loop from the cable connector to the process control system, and verify that the transmission of the measured value is zero error. The Memocheck Sim with quality certification is selected to certify the entire measuring point.

advantage
Fast and reliable function check: freely definable measured values and amplitudes for flexibility in installation, commissioning, troubleshooting and factory certification
Suitable for controlled environments: Quality certification and traceable calibration certificates are available
Improve the safety of the measuring loop: check the complete measuring loop from the cable connector to the process control system
All parameters available in one tool: pH, ORP, conductivity, dissolved oxygen, residual chlorine, turbidity and nitrate and SAC
Explosion-proof certified for use in explosion-hazardous areas

Application areas
Factory Certification
Installation and commissioning
fault diagnosis

technical parameters

 

Documentation/Manuals/Software

 

Accessories/Spare Parts

Source:Endress Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 多参数应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 多参数应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 多参数应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 多参数应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。