Technical Data
CompareAnalyser
| Measuring Principle | Potentiometric / ISE |
| Characteristic | Robust plastic housing All non-ex applications |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
Conductivity
| Measuring Principle | Conductive |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
Disinfection
| Measuring Principle | Free chlorine |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
Turbidity
| Measuring Principle | Single beam scattered light |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
pH
| Measuring Principle | Potentiometric |
| Application | Modular 4 wire controller Multichannel: 1 to 8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input, 2 to 8x current output, Alarmrelay, 2x relay, SD card for software update and copy & paste of setup |
| Material | Housing base: PC-FR Housing seal EPDM |
| Dimension | 237 x 194 x 162 mm 9.33 x 7.64 x 6.38 inch |
| Process temperature | -20 to 55 °C (0 to 130 °F) |
| Ingress protection | IP66 / IP67 |
| Input | 1 to 8x Memosens digital input 2x 0/4 to 20mA Input optional 2 to 4x Digital input optional |
| Output / communication | 2 to 8x 0/4 to 20 mA current outputs, alarmrelay 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet |
| Certificates, declarations and approvals | EAC, cCSAus |
The Liquiline CM448 digital multi-parameter transmitter is suitable for various process monitoring and control. The eight-channel controller saves time and money, enables seamless system integration, is easy to operate and reduces spare part inventory. The eight-channel device adapts to the measurement process and can connect 1 to 8 sensors as required. The Liquiline CM448R offers first-class performance, easy operation and ensures the highest process safety.
Advantages
Smart and simple: one controller for all parameters and conditions, intuitive user interface, automatic sensor recognition, plug-and-play with pre-calibrated Memosens sensors
Complete solution: eight-channel transmitter offering the highest application flexibility for every measuring task
Seamless system integration: unique combination of communication standards, compatible with various distributed control systems (DCS)
Simple and safe commissioning: use an SD card to conveniently configure similar devices, saving time and labor
Process control and safety: the built-in web server allows operators to remotely view diagnostic data and parameter settings, or access device parameters on any web browser via smartphone
Areas of application
The Liquiline CM448 multi-parameter transmitter is suitable for all non-hazardous applications, for example the following industries and their sub-industries:
Food&beverage
Life sciences
Power&energy
Water&wastewater
Chemical industry
The Liquiline CM444 is suitable for all common communication protocols and interfaces, such as:
0/4...20 mA
HART
PROFIBUS DP
Modbus TCP / Modbus RS485
EtherNet/IP
Web server
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
A
Source:Endress+Hauserwebsite public information
Case Studies
市政污水处理污水处理厂 · 多参数应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 多参数应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 多参数应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 多参数应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。