Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Ingress protection | IP20 transmitter IP66 optional Display |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
Disinfection
| Measuring Principle | Total chlorine |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch |
| Process temperature | -20...55°C / 0...130°F |
| Ingress protection | IP20 transmitter IP66 optional Display |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
Sludge Level
| Measuring Principle | Ultrasonic sensor |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Ingress protection | IP20 transmitter IP66 optional Display |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
Turbidity
| Measuring Principle | Single beam scattered light |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Ingress protection | IP20 transmitter IP66 optional Display |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
pH
| Measuring Principle | Potentiometric |
| Application | Modular 4 wire controller Multichannel:1-8 digital channels for Memosens protocol Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity 8 sensors connectable in any combination Functionality modular extendable at any time Plug and play for modules and sensors |
| Characteristic | Robust plastic housing All non-ex applications |
| Design | 8x Memosens input 2...8x current output alarmrelay 2x relay SD card for software update and copy & paste of setup |
| Material | Polycarbonate |
| Dimension | 220 (8.66) x 100 (3.94) x 98 (3.86) mm (inch) |
| Process temperature | -20...55°C / 0...130°F |
| Ingress protection | IP20 transmitter IP66 optional Display |
| Input | 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input optional |
| Output / communication | 2...8x 0/4...20 mA current outputs alarmrelay 4x relay ProfibusDP Modbus RS485 Modbus TCP Ethernet |
The Liquiline CM448R digital multiparameter transmitter is suitable for all kinds of process monitoring and control, and can be used in measuring applications with limited installation space. It enables fast and simple system integration, installation and operation, saving time and costs. The eight-channel device can easily be adapted to the measuring process, connecting 1 to 8 sensors as required. The Liquiline CM448R offers first-class performance, simple operation and maximum process safety.
Benefits
Space-saving and cost-reducing: compact eight-channel device for rail mounting in the cabinet.
Fast installation: no cutout in the cabinet door, one-click DIN rail mounting, minimum wiring
Simple, safe commissioning: save the configuration on an SD card for fast setup during repeated installation.
Simple operation and service: intuitive user panel, plug & play with pre-calibrated Memosens sensors, universal components for measuring all parameters.
Remote process control: via the integrated web server, operators can access diagnostic data remotely, configure parameters, or access device parameters through any web browser - even via smartphone.
Higher availability, lower costs:
Heartbeat Technology enables maintenance based on device status, easy verification of the measuring point, and supports the implementation of optimization measures.
Applications
The Liquiline CM448R multiparameter transmitter is suitable for all measurements in non-hazardous areas, including the following industries and their utilities:
Food & beverage
Life sciences
Power & energy
Water & wastewater
Chemical industry
The Liquiline CM448R is compatible with all common communication protocols and interfaces, such as:
0/4...20 mA
HART
PROFIBUS DP
Modbus TCP / Modbus RS485
EtherNet/IP
Webserver
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Related Models
Case Studies
市政污水处理污水处理厂 · 多参数应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 多参数应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 多参数应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 多参数应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对多参数的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。