Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

TMS01 多点温度计

 TMS01 多点温度计

多点温度计

By complying with the highest safety standards, iTHERM TMS01 can be customized for various applications. Bendable into a 3D layout, it provides a complete temperature profile just by using one nozzle. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available either with TC or RTD technology or with our iTHERM StrongSens.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
easy-to-use
suitable for hazardous areas
flanged process connection
light chemical processes
3D sensors distributions
modular design
replaceable sensors during shutdown
Thermowell / protection tube without (for direct contact sensors type)
with (for replaceable sensors)
with (for increased mechanical protection)
Multi-thermowells, each one dedicated to a sensor
Insert / probe mineral insulated (MI), flexible
mineral insulated (MI), flexible, with its own thermowell
Outer diameter protection tube / Insert 6,0 mm (0,24'')
8,0 mm (0,31")
10,29 mm (1/8")
Max. immersion length on request up to 30.000,00 mm (1181'')
Material protection tube/ thermowell 1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816)
Process connection flange:
2" ASME/ANSI B16.5 150
...600
3" ASME/ANSI B16.5 150
..600
4" ASME/ANSI B16.5 150
...600
6" ASME/ANSI B16.5 150
...600
8" ASME/ANSI B16.5 150
...600
DN80 EN/DIN 1092.1 PN10
...PN100
DN100 EN/DIN 1092.1 PN10
...PN100
DN125 EN/DIN 1092.1 PN10
...PN100
DN150 EN/DIN 1092.1 PN10
...PN100
DN200 EN/DIN 1092.1 PN10
...PN100
Tip shape straight
Operating temperature range Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 920 °C
(max. 1.688 °F)
Type N:
max. 1.150 °C
(max. 2.102 °F)
Type T:
max. 370 °C
(max. 698 °F)
Max. process pressure (static) at 20 °C: 100 bar (1450 psi)
Accuracy class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
Response time depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX
UL
FM
CSA
NEPSI
Certification SIL (transmitter only)
NEPSI

iTHERM MultiSens Flex TMS01
Multipoint thermometer
Direct contact TC/RTD temperature profile solution with 3D bendable sensors for oil, gas and petrochemical applications
Advantages
Easy-to-use device with modular and flexible design that can be installed directly for direct contact measurement or via a sensor-specific protection tube. The device can also be installed in an already positioned thermowell

Unlimited layout of the 3D sensor distribution for any desired process monitoring configuration

Modular product design, easy to install, integrate into the process and maintain, highly customizable

High insert process compatibility, complying with IEC 60584, ASTM E230 and IEC 60751 standards

Onboard electronic thermal protection for maximum product durability

Complies with different types of protection for use in hazardous locations, facilitating process integration
Field of application
The iTHERM TMS01 complies with the highest safety standards and can be customized for various applications. It can be bent into a 3D layout and provides a complete temperature profile using just one nozzle. The device can be configured with or without a thermowell for optimum response time, mechanical strength or sensor replaceability. It can use TC or RTD technology, as well as our iTHERM StrongSens.

Petrochemical industry

Oil and gas industry

Heavy chemical processes

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

市政污水处理

市政污水处理污水处理厂 · 热电偶应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对热电偶的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 热电偶应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对热电偶的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 热电偶应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对热电偶的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 热电偶应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对热电偶的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的热电偶,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。