Technical Data
CompareConductivity
| Measuring Principle | Inductive |
| Application | Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology |
| Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring |
| Measuring range | 100 µS/cm to 2000 mS/cm Cell constant k : 6.3 1/cm |
| Measuring principle | Inductive conductivity measurement |
| Design | Hygienic design with FDA certified virgin PEEK body including all hygienic certifications |
| Material | In contact with medium: Virgin PEEK |
| Process temperature | Max. 125 °C (max. 257 °F) For sterilization: up to 150 °C for max. 60 min (up to 302 °F for max. 60 min) |
| Process pressure | 12 bar abs up to 90 °C (174 psi abs up to 194 °F) |
| Temperature sensor | Pt 1000 |
| Connection | Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 |
| Ingress protection | IP67 |
| Output / communication | Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus |
| Certificates, declarations and approvals | nspection certificate 3.1, EN10204 Surface roughness test ISO4287/Ra (≤ 0,8 µm) Bio reactivity test USP Class VI US Food Contact Materials FDA CFR 21 EU Food Contact Materials (EG) 1935/2004 CN Food Contact Materials GB 4806 EHEDG EL Class I, 3-A |
Field of application
Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.
The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants, quality assurance
Leakage monitoring
It features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA
Benefits
Unique hygienic design avoids recontamination
With all hygienic certificates required in hygienic and sterile applications
Certified biocompatibility according to USP class VI
Compliant with EG 2023/2006 and 1935/2004
Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
Durable thanks to encapsulated, jointless design
Conductivity:
| Measuring Principle | Inductive | |
| Application | Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology | |
| Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring |
|
| Measuring range | 100 µS/cm to 2000 mS/cm Cell constant k : 6.3 1/cm |
|
| Measuring principle | Inductive conductivity measurement | |
| Design | Hygienic design with FDA certified virgin PEEK body including all hygienic certifications | |
| Material | In contact with medium: Virgin PEEK | |
| Process temperature | Max. 125 °C (max. 257 °F) For sterilization: up to 150 °C for max. 60 min (up to 302 °F for max. 60 min) |
|
| Process pressure | 12 bar abs up to 90 °C (174 psi abs up to 194 °F) |
|
| Temperature sensor | Pt 1000 | |
| Connection | Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50 | |
| Ingress protection | IP67 | |
| Output / communication | Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus | |
| Additional certifications | FDA, EHEDG, 3A Biological reactivity USP class VI part <87> and <88> EC Regulation No. 1935/2004 |
|
Related Models
Case Studies
市政污水处理污水处理厂 · 电导率应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电导率应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电导率应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电导率应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。