Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CLD18 Compact conductivity device

CLD18  Compact conductivity device

电导率仪

Configurable Models 11 models
Toroidal conductivity measuring system for hygienic applications
Compare

Conductivity

Measuring Principle Inductive
Application Food and beverage industries
Characteristic Specifically intended for use in beverage industry applications and especially suitable for:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 200 µS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK
Material Sensor: PEEK
Process connection 1.4435 (316L)
Seal: EPDM
Process temperature -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min
(Max. 266 °F at 87 psi up to 60 min)
Process pressure 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
Temperature sensor Pt 1000 (class B)
Connection Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
ISO 2852, SMS-2", Varivent N DN 40-125
Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC
Ingress protection IP69
Output / communication 0/4...20mA
IO-Link (option)
Certificates, declarations and approvals Inspection certificate 3.1, EN10204
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I, 3-A

Field of application
Smartec CLD18 is the cost-effective solution for all applications in beverage plants where small tubes are used and where the toroidal measurement is used as a switch function. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Smartec CLD18 ensures the Overall Equipment Effectiveness (OEE) of your plant thanks to fast and reliable CIP and optional IO-Link protocol.
The hygienic Smartec CLD18 measures toroidal conductivity in beverage applications:
Control of CIP processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants
Beer - Push water interphase
Beer - Water cut for brewing lines
Leakage monitoring
It features the following protocols and interfaces:
0/4...20mA
IO-Link (optional)

Benefits
Unique hygienic design avoids contamination
3-A approval
Compliant with EG 2023/2006 and 1935/2004
Suitable for cleaning-in-place (CIP)
Smart and easy integration into your plant infrastructure thanks to optional IO-Link protocol
Compact design permits installation in small tubes without restricting the flow

 

conductivity:

Measuring Principle Inductive
Application Food and beverage industries
Characteristic Specifically intended for use in beverage industry applications and especially suitable for:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring
Measuring range 200 µS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm
Measuring principle Inductive conductivity measurement
Design Hygienic design with FDA certified virgin PEEK
Material Sensor: PEEK
Process connection 1.4435 (316L)
Seal: EPDM
Process temperature -10 °C to 110 °C (14 °F to 230 °F)
Sterilization: max. 130 °C at 6 bar abs up to 60 min
(Max. 266 °F at 87 psi up to 60 min)
Process pressure 13 bar abs up to 50 °C (188.5 psi up to 122 °F)
7.75 bar abs at 110 °C (112 psi at 230 °F)
6.0 bar abs at 130 °C for max. 60 minutes
(87 psi at 266 °F for max. 60 minutes)
Temperature sensor Pt 1000 (class B)
Connection Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
ISO 2852, SMS-2", Varivent N DN 40-125
Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC
Ingress protection IP69
Output / communication 0/4...20mA IO-Link (option)
Additional certifications 3A, FDA, EHEDG
EC Regulation No. 1935/2004
Model Name
CLD18-AGCP 电导率仪
CLD18-AGGE 电导率仪
CLD18-AMDK 电导率仪
CLD18-AMOK 电导率仪
CLD18-ATDK 电导率仪
CLD18-BGGE 电导率仪
CLD18-BGGE+JAZ1 电导率仪
CLD18-BMDK 电导率仪
CLD18-BMOK 电导率仪
CLD18-BMOK 电导率仪
CLD18-BTDK 电导率仪
市政污水处理

市政污水处理污水处理厂 · 电导率应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导率应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导率应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导率应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。