Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CM444R rail type water analysis transmitter

CM444R rail type water analysis transmitter

导轨式水分析变送器

Scalable multi parameter transmitter, DIN rail and cabinet installation, suitable for various industries
Compare

Conductivity

Measuring Principle Conductive
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Disinfection

Measuring Principle Total chlorine
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output,
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

ORP / Redox

Measuring Principle Sensor ORP / Redox
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output,
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Sludge Level

Measuring Principle Ultrasonic sensor
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output,
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

Turbidity

Measuring Principle Single beam scattered light
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output,
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

pH

Measuring Principle Potentiometric
Application Modular 4 wire controller
Multichannel: 1 to 4 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
4 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic Robust plastic housing
All non-ex applications
Design 2 to 4x Memosens input, 2 to 8x current output,
Alarmrelay, 4x relay, SD card for software update and copy & paste of setup
Material DIN rail housing: PC-FR
Display seal: EPDM
Dimension 220 x 100 x 97 mm
8.66 x 3.94 x 3.82 inch
Process temperature 0 to 55 °C (32 to 130 °F)
Ingress protection Transmitter: IP20
Optional Display: IP66
Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals EAC, cCSAus

The Liquiline CM444R multi-parameter digital transmitter is suitable for all kinds of process monitoring and control and can be used in measurement applications with limited installation space. Fast and simple installation, operation and handling save time and costs. The four-channel controller can be expanded at any time and can connect up to 8 sensors to meet process measurement requirements. The Liquiline CM444R offers first-class performance, easy operation and ensures the highest process safety.

 

Advantages

Space and cost saving, compact, four-channel device, expandable at any time, rail mounting in the control cabinet

Fast installation: no opening in the control cabinet door, one-click DIN rail mounting, minimum wiring

Simple and safe commissioning: communication with other devices via SD card, convenient setup, saving time and costs

Simple operation and service: intuitive user panel, plug-and-play with pre-calibrated Memosens sensors, universal components for all parameters

Process control and safety: via the built-in web server, operators can remotely access diagnostic data and parameter settings, or access device parameters through any web browser - even via smartphone

 

Areas of application

The Liquiline CM444R multi-parameter transmitter is suitable for all non-hazardous areas, including the following industries and their utilities:

 

Food&beverage

Life sciences

Power&energy

Water&wastewater

Chemical industry

The Liquiline CM444R is compatible with all common communication protocols and interfaces, such as:

 

0/4...20 mA

HART

PROFIBUS DP

Modbus TCP / Modbus RS485

EtherNet/IP

Webserver

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

A

A

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 多参数应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 多参数应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 多参数应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 多参数应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对多参数的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的多参数,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。