Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FMB51 static pressure level gauge

FMB51 static pressure level gauge

静压式液位计

Configurable Models 2 models
The pressure sensor uses CONTITE components for static pressure level measurement
Compare

Continuous / Liquids

Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed
Rod version
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/ year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature -10°C...85°C
(14°F…212°F)
Process pressure / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100 mbar...10 bar
(1.5 psi...150 psi)
Main wetted parts Alloy C
316L
optional coating AuPt
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Max. measurement distance 100m (328ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals Overfill protection WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175
Drinking water approvals KTW/ NSF
Options Separate housing
Initial device settings
Overvoltage protection
Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
Observe ratio head pressure : hydrostatic pressure

Pressure

Measuring Principle Hydrostatic pressure
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Rod version
Supply voltage 4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy Standard 0.2 %
Optional 0.1 %
Long term stability 0.05 % of URL/year
Process temperature -10°C...85°C
(14°F…212°F)
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100 mbar...10 bar
(1.5 psi...150 psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material process membrane 316L, AlloyC
Gold-Rhodium
Material gasket Viton, EPDM, Kalrez, none
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Drinking water approvals KTW/ NSF
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

The Deltapilot FMB51 rod sensor uses the CONTITE measuring cell with a fixed process connection and is mainly used in the environmental sector to measure the level of liquid or paste-like media in open or closed vessels, with measurement unaffected by foam. The design complies with IEC 61508 and meets SIL2 functional safety requirements.

 

Advantages

Excellent repeatability and long-term stability

Turndown ratio: 100:1

Fully sealed CONTITE measuring cell: condensation-resistant, weather-protected; high reference accuracy: ±0.2%, optional: ±0.1%; minimal temperature influence

Point-to-point modules for measuring differential pressure, static pressure and pressure (Deltabar M - Deltapilot M - Cerabar M), e.g. replaceable display, universal electronics

Simple commissioning without operating tools

 

Areas of application

Hydrostatic sensors can be used for the following measurements:

 

Hydrostatic measurement of liquid and paste-like media in the process industry, process measurement, pharmaceutical and food industries

Measurement of liquid level, volume or mass

 

 

 

E+H Product Configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the boxes below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Model Name
FMB51-AA21JA1CGA80GGJB3A 静压式液位计
FMB51-AA21JA1CGA80GGJB3U 静压式液位计
市政污水处理

市政污水处理污水处理厂 · 静压测量应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 静压测量应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 静压测量应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 静压测量应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。