Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

FMB52 static pressure level gauge

FMB52 static pressure level gauge

静压液位计

Configurable Models 2 models
The pressure sensor uses CONTITE components for static pressure level measurement
Compare

Continuous / Liquids

Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed
Cable version
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Process pressure / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100 mbar...10 bar
(1.5 psi...150 psi)
Main wetted parts Alloy C
316L
Cable (PE/FEP)  
optional coating AuPt
optional coating AuRh
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Max. measurement distance 100 m (328 ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Marine approval GL/ ABS/ LR/ BV/ DNV
Drinking water approvals KTW/ NSF/ ACS
Options Separate housing
Initial device settings
Overvoltage protection
Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
Observe ratio head pressure : hydrostatic pressure
In case of an open tank or shaft use FMB53 with mounting clamp.

Pressure

Measuring Principle Hydrostatic pressure
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Cable version
Supply voltage 4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/year
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100 mbar...10 bar
(1.5 psi...150 psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material process membrane 316L, AlloyC,
Gold-Rhodium
PE, FEP
Material gasket Viton, EPDM, Kalrez, none
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Marine approvals GL/ ABS/ LR/ BV/ DNV
Drinking water approvals KTW/ NSF/ ACS
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

The Deltapilot FMB52 cable sensor uses a CONTITE measuring cell with a fixed process connection. It is mainly used in the process and environmental industries and measures the level of liquid or paste media in open or closed vessels, unaffected by foam. The design complies with IEC 61508 and meets SIL2 functional safety requirements.

Benefits:

  • Excellent repeatability and long-term stability

  • Turndown: 100:1

  • Hermetically sealed CONTITE measuring cell: condensation-resistant and climate-protected; high reference accuracy: ±0.2 %, optional ±0.1 %; minimal temperature effect

  • Point-to-point module measuring differential pressure, static pressure and pressure (Deltabar M - Deltapilot M - Cerabar M), e.g. replaceable display, universal electronics

  • Simple commissioning without tools

Application areas:

Hydrostatic sensors can be used for the following measurements:;

  • Static pressure measurement of liquids and pastes in the process industry, process measurement, pharmaceutical and food industries

  • Measurement of liquid level, volume or mass

  •  

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Model Name
FMB52-AA21JA1FGA35GGJB2UHC 静压液位计
FMB52-AA22IA1FGA15GGJB3U 静压液位计
市政污水处理

市政污水处理污水处理厂 · 静压测量应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 静压测量应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 静压测量应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 静压测量应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对静压测量的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的静压测量,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。