Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

TMT187 温度变送器

TMT187  温度变送器

温度变送器

The transmitter is designed for the transformation of an RTD Pt100 sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications.
Compare

Temperature transmitters

Measuring Principle
Input 1 x RTD (Pt100)
Output 1 x analog 4...20 mA
Auxiliary power supply 8...35 V DC (standard-version)
8...30 V DC (Ex-version)
Installation Terminal head form B
Accuracy (Pt100, -50...200 °C) <= 0,2 K
(Pt100, -58...392 °F) <= 0,4 °F
Galvanic isolation yes
Certification UL Ex IS
UL Ex NI
GOST Ex i
GL ship approval
GOST Metrology
FM IS,NI,Class I,Div.1+2,Group ABCD
CSA IS,NI,Class I,Div.1+2,Group ABCD
ATEX II1G EEx ia IIC T4/T5/T6
ATEX II3G Ex nA IIC Gc
ATEX II3D Ex tc IIIC Dc
ATEX II1G Ex ia IIC T6 Ga, II3D
ATEX II3G Ex nA IIC Gc, II3D
FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
CSA General Purpose
EAC Ex ia IIC T6 Ga
GL (German Lloyd)

Designed for signal transmission of resistance thermometers (RTD) Pt100 within a fixed measuring range. A 4 ... 20 mA standard current output signal is used for process measurement. Suitable for use in all industries, providing fast, convenient and economical temperature measurement with reliable and accurate measured values.

 

Benefits

High-accuracy measurement over the entire ambient temperature range.

Fault signal in the event of sensor open-circuit or short-circuit, preset in accordance with NAMUR NE 43.

Electromagnetic compatibility (EMC) in accordance with NAMUR NE 21, CE approval

Explosion protection: ATEX Ex ia and Zone 22 dust ignition protection in accordance with EN 50281-1, FM IS and CSA IS

Component certified in accordance with UL 3111-1

Marine approval

Galvanic isolation

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · 温度变送器应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 温度变送器应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 温度变送器应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 温度变送器应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对温度变送器的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度变送器,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。