电容料位计
The Nivector FTI26 is an economical level switch for powder applications in the food industry and various industries. The capacitive device has optimal anti-adhesion performance and extremely high sensitivity. It has certificates compliant with the standards of various industries. In addition, the FTI26 features IO-Link communication, meeting the requirements of Industry 4.0.
Advantages
Compact design for simple installation, even in confined spaces or hard-to-access applications
Meets all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); washdown-capable (IP69)
IO-Link reduces operating costs and operational complexity; the instrument can be configured conveniently via design software
Highest level of anti-adhesion performance and extremely high sensitivity
No need for separate adjustment for each medium
On-site function check via LED display
Application areas
For low-limit or high-limit detection of powdery and fine-grained bulk solids, e.g. plastic granules, grain, sugar, spices, coffee powder, washing powder
Process connection: G1" thread, Tri-Clamp 2" clamp
Temperature: -20...+80°C (-4...+176°F)
Pressure: -1...+6bar (-14.5...+86psi)
International explosion protection approval (dust explosion protection) and hygienic approval
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Technical Data
ComparePoint Level / Solids
| Measuring Principle | Capacitive Solid |
| Characteristic / Application | Compact for all types of powdered solids / small-grain bulk solids |
| Specialities | Active build-up compensation |
| Supply / Communication | 12 V...30 VDC |
| Ambient temperature | -20°C...+60°C (-4°F...+140°F) |
| Process temperature | -20°C...+80°C (-4°F...+176°F) |
| Main wetted parts | PC, ECTFE "Protector" FDA listed material PBT-GF (according to 21 CFR 177.1660) |
| Process connection | G1 |
| Communication | 12 V...30 VDC IO-Link |
| Safety approvals | ATEX, CSA C/US, IEC Ex, EAC Ex |
| Design approvals | EN 10204-3.1 |
| Hygienic approvals | 3-A, EHEDG |
Related Models
Case Studies
市政污水处理污水处理厂 · 电容应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电容的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电容应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电容的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电容应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电容的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电容应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电容的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。