Liquicap FMI51 is a reliable fully insulated rod probe for continuous level monitoring in liquids, particularly in build-up forming media and extremely high temperatures. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Compare

Continuous / Liquids

Measuring Principle Capacitive
Characteristic / Application Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)
Interface measurement Interfaces liquid / liquid also with emulsion layers
Specialities Inactive length
Factory calibrated
short response time by change of value
Supply / Communication 12-36V DC HART
PFM
Accuracy Repeatablity 0,1%
Linearity error for conductive liquids <0.5%
Ambient temperature -50°C...+70°C
-58°F...+158°F
Process temperature -80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limit Vacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted parts Insulation material: PTFE,PFA
316L
Process connection G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2
Flanges from DN25.../ASME 1".../JIS...
Process connection hygienic Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor length Total length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance 0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Communication 4...20mA HART
PFM
Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175
Hygienic approvals 3A, EHEDG
Marine approval GL/ ABS/ DNV
Options Separate housing
gas-tight probe seal
Application limits Insufficient clearance towards ceiling
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating

The FMI51 is the rod version. If a cable capacitive level transmitter is required, use the FMI52. For measuring light solids, use the FTC260.

The Liquicap FMI51/FM151 is a fully insulated rod probe for level monitoring in a wide range of liquids, and it also measures effectively in media prone to buildup and at extremely high temperatures. The measurement is unaffected by the dielectric constant (DC). Used together with the Fieldgate FXA320 (remote reading of measured values via Internet technology), Liquicap is the ideal choice for inventory management solutions.

Benefits:

  • Compliant with IEC 61508, can be used in safety systems up to functional safety level SIL2

  • Numerous certificates and approvals for reliable use and a wide range of applications

  • No calibration required (factory preset). No calibration is needed when measuring media with a conductivity of 100 μS/cm and higher

  • Process wetted parts made of corrosion-resistant, FDA-approved materials

  • Menu-guided on-site configuration via plain text display (optional)

  • Two-stage overvoltage protection

Application areas:

The instrument is unaffected by the dielectric constant (DC); liquids have a conductivity of 100 μS/cm, and multiple liquids can be measured without recalibration.

  • Process connection: flange and thread

  • Process pressure: -1...+100 bar (+1,450 psi)

  • Measuring range: 0.1...4.0 m (0.3...13 ft)

  • Temperature: -80...+200 °C (-112...+392 °F)

  • International explosion protection approval, WHG overflow protection, SIL, hygienic approval, marine approval

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
FMI51-A1AGCJB2A2A 电容液位计
FMI51-A1AGDJA2A1A 电容液位计
FMI51-A1AGDJA3A1F 电容液位计
FMI51-A1ATCJB2A1A 电容液位计
FMI51-A1BAFJB2A1A 电容液位计
FMI51-A1BTDJA1A1A 电容液位计
FMI51-A1BTDJB3A1A 电容液位计
FMI51-A2AGDJA2A1A 电容液位计
FMI51-A2AGDJB2A1A 电容液位计
FMI51-H1BGEJA3A1A 电容液位计
市政污水处理

市政污水处理污水处理厂 · 电容应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电容的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电容应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电容的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电容应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电容的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电容应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电容的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电容,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。