Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

TW15 棒材保护套管

TW15 棒材保护套管

棒材保护套管

Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.
Compare

Thermowell

Measuring Principle Bar stock Thermowell
Characteristic / Application metric style
DIN 43772 Form 4/4F
flanged process connection or weld-in with neck
Head connection external thread:
M24 x 1.5
1/2" NPT
Maximum standard immersion length 250 mm (9,84")
Max. immersion length on request 400 mm (15,75")
Process connection For welding with welding socket TA115 as accessory
For flanging with the following flange sizes:
DN25 PN40 B1
DN40 PN40 B1
DN50 PN40 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1 1/2" 150 RF
Thermowell root diameter 18 mm (0,71")
24 mm (0,94")
Medium contact material 1.4571 (316Ti)
2.4819 (Alloy C276)
1.7335 (13CrMo4-5)
Titan
Duplex SAF2205
C22.8
1.5415 (16Mo3)
1.7380 (10CrMo 9 10)
Wetted part finishing (Ra) < 0.8 µm (31.50 µin)
< 1.6 µm (63.00 µin)
Tip shape conical
Temperature range -200...1.100 °C (-328...2.012 °F)
Max. process pressure (static) 400 bar (5802 psi)
Max. process pressure at 400 °C 400 bar (5802 psi)

TW15 bar stock thermowell, a thermowell made from solid drilled bar stock, mainly for demanding applications or general use

Benefits

  • The extension length, insertion depth and dimensions of the thermowell can be selected according to process requirements

  • Wide choice of dimensions, materials and process connections

  • Can be customized to customer specifications

  • Process connection by welding or flange

Applications

Because the process conditions are demanding, the strength of the thermowell must be calculated precisely. Dye penetrant testing, ultrasonic testing, helium leak testing, pressure endurance testing and various non-destructive material tests verify the quality of the material and workmanship.

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products to compare in the fields below. Up to three products can be compared.

 

Technical documentation

   

Technical data

 

 

   

Documents/Manuals/Software

 

 

   

Accessories/Spare parts

 

 

Source: Endress+Hauser public information from the website

市政污水处理

市政污水处理污水处理厂 · 温度套管应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对温度套管的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度套管,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 温度套管应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对温度套管的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度套管,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 温度套管应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对温度套管的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度套管,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 温度套管应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对温度套管的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的温度套管,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。