Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

80F 质量流量计

 80F 质量流量计

质量流量计

Promass F has a long standing reputation as a highly accurate and robust device. It is suited for a broadest range of applications. Combined with the proven Promass 80 transmitter with push buttons, Promass 80F offers highest measurement performance for liquids and gases under varying, demanding process conditions.
Compare

Density

Measuring Principle Coriolis
Characteristic / Application The universal and multivariable flowmeterfor liquids and gases
Ambient temperature -20...+65°C
(-4...+140°F)
Process temperature -50...+350°C
(-58...+662°F)
Process pressure PN 16...100
Cl 150...600
JIS 10...63K
Wetted parts 904L/1.4539
Alloy C-22
Output 4...20mA
Pulse/Frequency
Status
Certificates / Approvals ATEX
FM
CSA
TIIS

Density/Concentration

Measuring Principle Coriolis
Product headline The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, EHEDG, FDA

Gas

Measuring Principle Coriolis
Product headline The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A,, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, EHEDG, FDA

Liquids

Measuring Principle Coriolis
Product headline The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, EHEDG, FDA

Steam

Measuring Principle Coriolis
Product headline The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, EHEDG, FDA

The Promass F series has earned an excellent reputation for its high-precision measurement and equipment robustness, with a wide range of applications. With the Promass 80 transmitter, it provides precise flow measurement of liquids and gases under changing, demanding process conditions.

Benefits

  • Modular device and operating concept for greater efficiency

  • Data backup improves process quality

  • Compact multivariable flow measuring instrument

  • Balanced two-tube measuring system design with good vibration resistance

  • Rugged construction, unaffected by external pipe forces

  • No inlet/outlet straight pipe runs required, easy installation

Application areas

 

 

The Coriolis mass flow measuring principle is independent of the physical properties of the fluid, such as viscosity and density.

  • Extremely precise measurement of liquids and gases such as oils, lubricants, fuels, liquefied gases, solvents, food products and compressed gases (natural gas)

  • Fluid temperature up to +350 °C (+662 °F)

  • Process pressure up to 100 bar (1450 psi)

  • Mass flow measurement up to 2200 t/h (80 850 lb/min)

Hazardous area approval

  • ATEX, FM, CSA, TIIS

  •  

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

市政污水处理

市政污水处理污水处理厂 · 质量流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 质量流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 质量流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 质量流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。