Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CA80TP 总磷分析仪

CA80TP 总磷分析仪

总磷分析仪

Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, that's why continuous monitoring of this parameter is essential. The Liquiline System TP analyzer offers precise online measurement of total phosphorus and ensures highest process safety. Automatic calibration and cleaning save you operating costs while advanced diagnostics with remote access support you in providing process documentation to the authorities.
Compare

Analyser

Measuring Principle Colorimetric
Characteristic Analyzer for total phosphorus
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 to 40 °C (39.2 to 104 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure At atmospheric pressure, < 0.2 bar
Sample flow rate Min. 30 ml/min
Consistency of the sample Low solid content (TS<50 mg/l), homogeneous
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Self-priming analyzer with optical dosing unit l
Dilution module (optional)
Digital communication for remote access
Application Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz
Output / communication 2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP
Input 1 measuring channel
1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional)
Measuring range 0 to 2 mg/l
0.05 to 10 mg/l
0.5 to 50 mg/l
Consumables Reagents and standard solutions CY80TP are necessary for the operation

Phosphorus is the decisive factor for excessive algae and plant growth in water bodies, making continuous measurement of this parameter very important. The Liquiline System TP analyzer performs high-precision online total phosphorus measurement, ensuring maximum process safety. Automatic calibration and cleaning save operating costs, and advanced diagnostics with remote access provide process documentation to the relevant authorities.

 

Benefits

The molybdenum blue method conforms to EN ISO 6878:2004, ensuring comparability with laboratory results

Meets industrial requirements: the analyzer is especially suitable for environmental monitoring and industrial and municipal wastewater monitoring

Fast and simple process connection: self-priming version for direct installation or Y-type pretreatment for use in a bypass

Highest safety level: the reactor and all connector parts feature software-controlled safety; a light barrier prevents overdosing of reagents and samples, providing additional safety

Reliable sample transport and high-precision reagent dosing: the peristaltic pump can handle samples containing solids. A light barrier ensures repeatable high-precision reagent dosing

Optional cooling unit extends the service life of the reagents

Simple functional upgrade to a complete measuring station: simply add modules and connect Memosens sensors

 

Application

The Liquiline System total phosphorus analyzer monitors:

The inlet and outlet of wastewater treatment plants for documentation and calculation of purification capacity

Industrial wastewater treatment plant discharge volumes to determine discharge fees, forming the basis of the “polluter pays principle”

Process water

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

A

   

Measuring Principle Video

Source:Endress+Hauserwebsite public information

市政污水处理

市政污水处理污水处理厂 · EH-ONLINE应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · EH-ONLINE应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · EH-ONLINE应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · EH-ONLINE应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对EH-ONLINE的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的EH-ONLINE,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。