质量流量计 8S1B
The Promass S features an advanced hygienic design and is Endress+Hauser's industry-optimized measuring solution that meets all hygienic requirements and can be installed and used in the food and beverage industry. Combined with the smallest transmitter housing currently available, it delivers full performance in minimum space. Designed for installation in confined spaces, the Promass S 100 is the ideal choice for system integrators, skid manufacturers and equipment manufacturers.
Benefits
Lower installation costs: fully self-draining measuring tube design enables complete horizontal installation
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no upstream/downstream straight pipe run requirements
Small transmitter: full functionality in minimal space
Time-saving on-site operation without additional software and hardware: built-in web server
Integrated verification: built-in Heartbeat Technology
Application areas
The measuring principle is independent of the physical properties of the fluid (e.g. viscosity and density).
A flowmeter specially designed for hygienic applications with optimum cleanability.
Device features
Various hygienic process connections
3A and EHEDG certification
Fast recovery after CIP/SIP cleaning
Rugged, ultra-compact one-piece transmitter housing
High degree of protection: IP69K
Field display unit available
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the product order codes to be compared in the input boxes below; a maximum of three products can be compared
Technical documentation
Technical specifications
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauser website public information
Technical Data
CompareLiquids
| Measuring Principle | |
| Product headline | The easy‐to‐clean flowmeter with self‐drainable singletube system and an ultra‐compact transmitter. Dedicated for applications requiring optimal cleanability under hygienic conditions. |
| Sensor features | Increased process safety – easy cleanable and fully self‐drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. |
| Transmitter features | Space‐saving transmitter – full functionality on smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra‐compact transmitter housing. High ingress protection: IP69K. |
| Nominal diameter range | DN 8 to 50 (⅜ to 2") |
| Wetted materials | Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4301 (304), 1.4404 (316L) |
| Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69K |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, TIIS |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD Attestation) PED, CRN 3-A, EHEDG |
Case Studies
市政污水处理污水处理厂 · 质量流量计应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 质量流量计应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 质量流量计应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 质量流量计应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对质量流量计的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的质量流量计,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。